文献速递腹部技术与安全CT

计算机断层扫描能否作为超声内镜的替代方法用于小胃胃肠道间质瘤的筛查和监测?

Could computed tomography be used as a surrogate of endoscopic ultrasonography in the screening and surveillance of small gastric Gastrointestinal stromal tumors?
PubMed 文献 · Eur J Radiol · 2020-12-02

回顾性纳入2007年9月至2019年11月病理证实的162例小胃胃肠道间质瘤(≤2 cm),其中36例经内镜和超声内镜识别后行增强CT,43例术前仅行CT。CT对经内镜和超声内镜识别的1–2 cm肿瘤检出率为100%,而仅CT为75%(p=0.02);对≤1 cm肿瘤检出率均低(33.3% vs. 14.8%,p=0.372)。CT可用于1–2 cm肿瘤的监测替代超声内镜,但不能用于筛查。

要点

  • CT对经内镜和超声内镜识别的1–2 cm胃间质瘤检出率达100%,但仅CT筛查时降至75%(p=0.02)。
  • CT对≤1 cm胃间质瘤检出率低,经内镜和超声内镜识别后为33.3%,仅CT为14.8%(p=0.372)。
  • CT检出的不均匀强化和钙化分别与超声内镜不均匀回声(ρ=0.66)和强回声灶(ρ=0.79)强相关。

关键影像表现/征象

  • CT对经内镜和超声内镜识别的1–2 cm胃间质瘤检出率为100%,仅CT为75%(p=0.02)。
  • CT对≤1 cm胃间质瘤检出率:经内镜和超声内镜识别后为33.3%,仅CT为14.8%(p=0.372)。
  • CT检出的不均匀强化与超声内镜不均匀回声强相关(Spearman ρ=0.66,p<0.001)。
  • CT检出的钙化与超声内镜强回声灶强相关(Spearman ρ=0.79,p<0.001)。
  • CT检出的坏死与超声内镜囊性间隙中度相关(Spearman ρ=0.42,p=0.02);CT与超声内镜评估的不规则边界无相关性。

临床应用与阅片要点

  • 作者认为CT可能可考虑作为超声内镜的替代方法用于1–2 cm胃间质瘤的监测,而非≤1 cm者。
  • 作者认为CT不能用作≤1 cm或1–2 cm胃间质瘤的筛查手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate whether computed tomography (CT) could be used for screening and surveillance of small gastric gastrointestinal stromal tumors (gGISTs).

METHOD: A total of 162 pathologically confirmed small gGISTs (≤2 cm) between September 2007 and November 2019 were retrospectively enrolled. Thirty-six lesions received contrast-enhanced CT after they were identified by endoscopy and EUS, and forty-three lesions received CT alone before surgery. The detection rate of CT for ≤1 cm gGISTs (micro-gGISTs) and 1-2 cm gGISTs (mini-gGISTs) was investigated, and the detection rate of CT alone was compared with that of CT following endoscopy and EUS. The relationship between EUS- and CT-detected high-risk features were assessed.

RESULTS: CT demonstrated a favorable detection rate for mini-gGISTs previously identified by EUS and endoscopy, whereas CT alone showed an inferior detection rate (100 % vs. 75 %, p = 0.02). CT showed a poor detection rate for micro-gGISTs, both for lesions received CT after identified by EUS and endoscopy, and those received CT alone (33.3 % vs. 14.8 %, p = 0.372). CT-detected heterogeneous enhancement pattern and presence of calcification were strongly correlated with heterogeneous echotexture (Spearman's ρ=0.66, p < 0.001) and echogenic foci (Spearman's ρ=0.79, p < 0.001) on EUS, respectively. CT-detected necrosis was moderately correlated with cystic spaces on EUS (Spearman's ρ=0.42, p = 0.02). No correlation was found between EUS- and CT- assessed irregular border.

CONCLUSIONS: CT could potentially be considered as a surrogate of EUS for surveillance of mini-gGISTs instead of micro-gGISTs, whereas couldn't be used as a screening modality for either micro- or mini-gGISTs.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Jia X, Liu Y, Zhao J, et al. Could computed tomography be used as a surrogate of endoscopic ultrasonography in the screening and surveillance of small gastric Gastrointestinal stromal tumors? Eur J Radiol. 2020. PMID: 33338760. doi:10.1016/j.ejrad.2020.109463

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。