胃平滑肌瘤的对比增强CT影像诊断评分模型:与胃肠道间质瘤的鉴别诊断
回顾性纳入2013年1月至2018年8月经病理证实的胃平滑肌瘤46例和胃肠道间质瘤63例,分析对比增强CT特征并建立评分模型。多因素分析确定5个独立预测因子,评分模型在9分阈值下AUC为0.95,敏感度95.65%、特异度79.37%。总分1–17分分为四组,诊断概率分别为0%、45%、83%和100%。
要点
- 评分模型总分1–17分,1–7分、7–10分、10–13分、13–17分对应的胃平滑肌瘤诊断概率分别为0%、45%、83%和100%。
- 9分阈值下模型AUC为0.95,敏感度95.65%、特异度79.37%、阳性预测值77.19%、阴性预测值96.15%、诊断准确率86.24%。
- 5个独立预测因子为:累及食管胃结合部、无坏死、无溃疡、强化程度及长径/短径比值。
关键影像表现/征象
- 多因素logistic回归分析显示累及食管胃结合部是胃平滑肌瘤的独立预测因子(OR 367.9,95%CI 5.8–23302.8,P=0.005)。
- 强化程度是独立预测因子(OR 9.3,95%CI 3.2–27.4,P<0.001),长径/短径比值也是独立预测因子(OR 170.9,95%CI 8.4–3493.4,P=0.001)。
诊断标准与关键数值
- 评分模型总分范围为1–17分,分为四组:1–7分、7–10分、10–13分、13–17分,对应的胃平滑肌瘤诊断概率分别为0%、45%、83%和100%。
- 在9分阈值下,评分模型的AUC为0.95,敏感度95.65%、特异度79.37%、阳性预测值77.19%、阴性预测值96.15%、诊断准确率86.24%。
- 基于评分的四组间胃平滑肌瘤诊断概率呈递增趋势(P<0.001)。
临床应用与阅片要点
- 阅片时可关注肿瘤是否累及食管胃结合部、有无坏死和溃疡、强化程度及长径/短径比值,这些特征有助于鉴别胃平滑肌瘤与胃肠道间质瘤。
- 根据评分模型总分对照四组诊断概率(0%、45%、83%、100%),辅助判断胃平滑肌瘤的可能性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate CT findings and develop a diagnostic score model to differentiate GLMs from GISTs.
METHODS: This retrospective study included 109 patients with pathologically confirmed GLMs (n = 46) and GISTs (n = 63) from January 2013 to August 2018 who received CE-CT before surgery. Demographic and radiological features was collected, including lesion location, contour, presence or absence of intralesional necrosis and ulceration, growth pattern, whether the tumor involved EGJ, the long diameter (LD) /the short diameter (SD) ratio, pattern and degree of lesion enhancement. Univariate analyses and multivariate logistic regression analyses were performed to identify independent predictors and establish a predictive model. Independent predictors for GLMs were weighted with scores based on regression coefficients. A receiver operating characteristic (ROC) curve was created to determine the diagnostic ability of the model. Overall score distribution was divided into four groups to show differentiating probability of GLMs from GISTs.
RESULTS: Five CT features were the independent predictors for GLMs diagnosis in multivariate logistic regression analysis, including esophagogastric junction (EGJ) involvement (OR, 367.9; 95 % CI, 5.8-23302.8; P = 0.005), absence of necrosis (OR, 11.9; 95 % CI, 1.0-138. 1; P = 0.048) and ulceration (OR, 151.9; 95 % CI, 1.4-16899.6; P = 0.037), degree of enhancement (OR, 9.3; 95 % CI, 3.2-27.4; P < 0.001), and long diameter/ short diameter (LD/SD) ratio (OR,170.9; 95 % CI, 8.4-3493.4; P = 0.001). At a cutoff of 9 points, AUC for this score model was 0.95, with 95.65 % sensitivity, 79.37 % specificity, 77.19 % PPV, 96.15 % NPV and 86.24 % diagnostic accuracy. An increasing trend was showed in diagnostic probability of GLMs among four groups based on the score (P < 0.001).
CONCLUSIONS: The newly designed scoring system is reliable and easy-to-use for GLMs diagnosis by distinguishing from GISTs, including EGJ involvement, absence of ulceration and necrosis, mild enhancement and high LD/SD ratio. The overall score of model ranged from 1 to 17 points, which was divided into 4 groups: 1-7 points, 7-10 points, 10-13 points and 13-17 points, with a diagnostic probability of GLMs 0%, 45 %, 83 % and 100 %, respectively.
引用
- Xu JX, Ding QL, Lu YF, et al. A scoring model for radiologic diagnosis of gastric leiomyomas (GLMs) with contrast-enhanced computed tomography (CE-CT): Differential diagnosis from gastrointestinal stromal tumors (GISTs). Eur J Radiol. 2020. PMID: 33310552. doi:10.1016/j.ejrad.2020.109395
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。