文献速递胸部腹部技术与安全CT

光谱探测器CT在食管癌治疗前局部区域评估中的价值

Value of spectral detector CT for pretherapeutic, locoregional assessment of esophageal cancer.
PubMed 文献 · Eur J Radiol · 2020-11-21

回顾性纳入74例经活检证实的食管癌患者,评估光谱探测器双能CT低keV虚拟单能图像(VMI)和碘叠加图(IO)对肿瘤及区域淋巴结的显示价值。VMI40-60keV可提高图像衰减和信噪比,IO和VMI40keV在淋巴结显示和肿瘤浸润诊断确定性上评分最高,但联合多种图像检测晚期肿瘤浸润的敏感度仅42.4%。

要点

  • VMI40keV较常规图像显著提高肿瘤/食管、肿瘤/膈肌和肿瘤/肝脏的对比噪声比。
  • IO和VMI40keV对淋巴结显示及肿瘤浸润诊断确定性的主观评分最高。
  • 联合常规图像、VMI40-70keV和IO检测晚期肿瘤浸润(T3/T4)敏感度42.4%、特异度82.0%、准确率56.3%。

诊断标准与关键数值

  • VMI40-60keV在全部评估ROI上较常规图像显示显著更高的衰减和信噪比,峰值位于VMI40keV(p < 0.05)。
  • 肿瘤/食管对比噪声比VMI40keV 7.7 ± 4.7 vs 常规图像 2.3 ± 1.5,VMI40keV显著更高(p < 0.05)。
  • 肿瘤/膈肌对比噪声比VMI40keV 9.0 ± 5.5 vs 常规图像 2.2 ± 1.7,VMI40keV显著更高(p < 0.05)。
  • 肿瘤/肝脏对比噪声比VMI40keV 4.3 ± 5.5 vs 常规图像 1.9 ± 2.1,VMI40keV显著更高(p < 0.05)。
  • 联合常规图像、VMI40-70keV和IO检测晚期肿瘤浸润(T3/T4)的敏感度42.4%、特异度82.0%、准确率56.3%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the diagnostic value of spectral detector dual-energy CT-derived low-keV virtual monoenergetic images (VMI) and iodine overlays (IO) for locoregional, pretherapeutic assessment of esophageal cancer.

METHOD: 74 patients with biopsy-proven esophageal cancer who underwent pre-therapeutic, portal-venous-phase staging examinations of the chest and abdomen were retrospectively included. Quantitative image analysis was performed ROI-based within the tumor, healthy esophageal wall, peri-esophageal lymph nodes, azygos vein, aorta, liver, diaphragm, and mediastinal fat. Two radiologists evaluated delineation of the primary tumor and locoregional lymph nodes, assessment of the celiac trunk and diagnostic certainty regarding tumor infiltration in conventional images (CI), VMI from 40 to 70 keV and IO. Moreover, presence/absence of advanced tumor infiltration (T3/T4) was determined binary using all available images.

RESULTS: VMI40-60keV showed significantly higher attenuation and signal-to-noise ratio compared to CI for all assessed ROIs, peaking at VMI40keV (p < 0.05). Contrast-to-noise ratio of tumor/esophagus (VMI40keV/CI: 7.7 ± 4.7 vs. 2.3 ± 1.5), tumor/diaphragm (VMI40keV/CI: 9.0 ± 5.5 vs. 2.2 ± 1.7) and tumor/liver (4.3 ± 5.5 vs. 1.9 ± 2.1) were all significantly higher compared to CI (p < 0.05). Qualitatively, lymph node delineation and diagnostic certainty regarding tumor infiltration received highest ratings both in IO and VMI40keV, whereas vascular assessment was rated highest in VMI40keV and primary tumor delineation in IO. Sensitivity/Specificity/Accuracy for detecting advanced tumor infiltration using the combination of CI, VMI40-70keV and IO was 42.4 %/82.0 %/56.3 %.

CONCLUSIONS: IO and VMI40-60keV improve qualitative assessment of the primary tumor and depiction of lymph nodes and vessels at pretherapeutic SDCT of esophageal cancer patients yet do not mitigate the limitations of CT in determining tumor infiltration.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zopfs D, Große Hokamp N, Reimer R, et al. Value of spectral detector CT for pretherapeutic, locoregional assessment of esophageal cancer. Eur J Radiol. 2020. PMID: 33302024. doi:10.1016/j.ejrad.2020.109423

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。