超声造影用于胆道缺血:一种可能的新临床适应证
本研究在胆道缺血模型中探讨超声造影(CEUS)评估胆道灌注的能力,分为两部分:首先用血管示踪剂验证胆管壁CEUS增强代表胆道灌注,其次以微血管密度为参考评估CEUS诊断胆道缺血的能力。结果显示胆管壁CEUS增强与灌注一致,CEUS评分≥3分时诊断胆道缺血的敏感度87.8%、特异度98.3%、准确率93.8%、AUC 0.98。
要点
- 胆管壁CEUS增强可代表胆道灌注,灌注中断时无增强,恢复后增强。
- 缺血手术组微血管密度更低、增强水平更低、CEUS评分更高(均P < .001)。
- CEUS评分≥3分(动脉期胆管壁明显减低或未增强,或门静脉期快速廓清至无增强)诊断胆道缺血敏感度87.8%、特异度98.3%。
关键影像表现/征象
- 胆道灌注中断时胆管壁血管示踪剂未染色且CEUS无增强,恢复后呈蓝色染色并增强。
- 缺血手术组胆管壁微血管密度测量值更低(P < .001)。
- 缺血手术组胆管壁增强水平更低(P < .001)。
- 缺血手术组CEUS评分更高(P < .001)。
诊断标准与关键数值
- CEUS评分≥3分定义为动脉期胆管壁明显减低至低增强或无增强,或门静脉期快速廓清至无增强。
- 以CEUS评分≥3分为阈值,诊断胆道缺血的敏感度87.8%、特异度98.3%、准确率93.8%、AUC 0.98。
临床应用与阅片要点
- 观察胆管壁在动脉期和门静脉期的增强水平及廓清情况,可按CEUS评分(评分越高增强减低越明显)进行半定量评估。
- 动脉期胆管壁明显低增强或无增强、或门静脉期快速廓清至无增强,对应CEUS评分≥3分。
局限性
- 结论指出诊断性能是在实验动物环境中获得的。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Biliary perfusion is considered to contribute to biliary diseases, but routine imaging methods are insufficient to show it. This research investigated the ability of contrast-enhanced ultrasound (CEUS) for biliary perfusion in a biliary ischemia model.
METHODS: This research consisted of 2 parts. First, to determine whether CEUS enhancement of the tiny biliary wall represents biliary perfusion, a vascular tracer was used as a reference to evaluate the consistency with the enhancement of the biliary wall on CEUS and the staining by the vascular tracer under the conditions of occluded and recovered biliary perfusion. In the second part, the ability of CEUS for biliary ischemia was further evaluated with microvascular density measurement as a reference. The enhancement patterns were assigned CEUS scores, in which higher scores meant more decreased enhancement, and the diagnostic ability of CEUS was assessed by a receiver operating characteristic curve analysis.
RESULTS: The biliary wall was unstained by the vascular tracer and nonenhanced on CEUS when biliary perfusion was interrupted and was stained blue and enhanced after recovery. The biliary wall in the ischemia surgery group showed lower microvascular density measurements (P < .001), decreased enhancement levels (P < .001), and higher CEUS scores (P < .001). When a CEUS score of 3 or higher (obvious decrease of the biliary wall to hypoenhancement or nonenhancement in the arterial phase or rapid wash-out to nonenhancement in the portal venous phase) was applied, CEUS had sensitivity of 87.8%, specificity of 98.3%, accuracy of 93.8%, and an area under the receiver operating characteristic curve of 0.98.
CONCLUSIONS: Contrast enhancement of the biliary wall on CEUS represents biliary perfusion and has reasonably good diagnostic performance for biliary ischemia in an experimental animal setting.
引用
- Zheng BW, Wu T, Ju JX, et al. Contrast-Enhanced Ultrasound for Biliary Ischemia: A Possible New Clinical Indication. J Ultrasound Med. 2020. PMID: 33270273. doi:10.1002/jum.15577
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。