文献速递外周血管腹部US

利用腹主动脉多视角超声成像增强横向对比度

Enhancing Lateral Contrast Using Multi-perspective Ultrasound Imaging of Abdominal Aortas.
PubMed 文献 · Ultrasound Med Biol · 2020-12-19

本研究通过物理平移超声探头在腹主动脉上获取-45°至+45°共七个角度的二维横断面多视角图像,并以自动特征检测配准。在1个体模和11名志愿者中,自动检测在77组图像中成功62组,志愿者多视角复合图像在整个心动周期内对比噪声比从0.6±0.1提高至1.2±0.2。

要点

  • 多视角复合图像在志愿者中整个心动周期内对比噪声比从0.6±0.1提高至1.2±0.2。
  • 自动配准依赖主动脉与脊柱的自动特征检测,77组图像中成功62组。
  • 通过探头物理平移在腹主动脉上获得-45°至+45°七个角度的大角度图像。

诊断标准与关键数值

  • 自动特征检测配准在77组图像中成功62组。
  • 志愿者多视角复合图像对比噪声比在整个心动周期内从0.6±0.1提高至1.2±0.2。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Vascular ultrasound imaging is inherently hampered by low lateral resolution and contrast. Steering of the ultrasound beams can be used to overcome these limitations in superficial artery imaging because the aperture-to-depth ratio is relatively high. However, in arteries located at larger depths, the steered beams do not overlap for larger steering angles. In this study, the ultrasound probe is physically translated over the abdomen to create large angles between acquisitions, while maintaining overlap on the abdominal aorta. In one phantom setup and 11 volunteers, 2-D cross-sectional multi-perspective ultrasound images of the abdominal aorta were acquired using seven angles between -45° and +45°. Automatic registration of the recorded images was performed by automatic feature detection of the aorta and spine. This automatic detection was successful in 62 out of 77 image sets. Compounded multi-perspective images showed an increase of contrast-to-noise ratios from 0.6 ± 0.1 to 1.2 ± 0.2 over the entire heart cycle in volunteers.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Petterson NJ, van Sambeek MRHM, van de Vosse FN, et al. Enhancing Lateral Contrast Using Multi-perspective Ultrasound Imaging of Abdominal Aortas. Ultrasound Med Biol. 2020. PMID: 33349515. doi:10.1016/j.ultrasmedbio.2020.09.023

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。