持续增加的翻转时间可改善自由呼吸三维钆延迟强化MRI的血流抑制并优化暗血对比
研究前瞻性纳入50例既往心律失常患者,分别采用固定翻转时间(n=25)或动态翻转时间(n=25)行自由呼吸高各向同性分辨率三维暗血钆延迟强化MRI。固定组测得的平均翻转时间增加速率为2.3±0.5 ms/min并用于动态组,动态组平均血池信号强度较固定组降低72%(P<0.001),整体图像质量、观察者信心和瘢痕勾画均显著改善。
要点
- 动态翻转时间使血池信号强度较固定翻转时间降低72%(P<0.001),暗血对比更优。
- 固定组测得的翻转时间平均增加速率为2.3±0.5 ms/min,可作为动态翻转时间的输入参数。
- 动态翻转时间组整体图像质量(P=0.02)、观察者信心(P=0.02)和瘢痕勾画(P=0.01)均显著改善。
关键影像表现/征象
- 在左心室血池绘制感兴趣区评估平均信号强度,作为血池抑制的指标。
- 动态翻转时间组平均血池信号强度较固定翻转时间组降低72%(P<0.001)。
- 整体图像质量(P=0.02)、观察者信心(P=0.02)和瘢痕勾画(P=0.01)在动态翻转时间组显著改善。
诊断标准与关键数值
- 固定翻转时间组通过三维采集前后的Look-Locker扫描获得血池零化翻转时间每分钟平均增加2.3±0.5 ms/min,该平均增量作为动态翻转时间组初始血池零化翻转时间动态增量的计算输入。
- 整体图像质量、观察者信心和瘢痕勾画采用3分制评分。
- 三维暗血钆延迟强化数据在46/50例(92%)患者中成功采集。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
MATERIALS AND METHODS: Fifty consecutive patients with previous cardiac arrhythmias, scheduled for high-resolution 3D LGE MRI, were prospectively enrolled between October 2017 and February 2020. Free-breathing 3D dark-blood LGE MRI with high isotropic resolution (1.6 × 1.6 × 1.6 mm) was performed using a conventional fixed TI (n = 25) or a dynamic TI (n = 25). The average increase in blood nulling TI per minute was obtained from Look-Locker scans before and after the 3D acquisition in the first fixed TI group. This average increment in TI was used as input to calculate the dynamic increment of the initial blood nulling TI value as set in the second dynamic TI group. Regions of interest were drawn in the left ventricular blood pool to assess mean signal intensity as a measure for blood pool suppression. Overall image quality, observer confidence, and scar demarcation were scored on a 3-point scale.
RESULTS: Three-dimensional dark-blood LGE data sets were successfully acquired in 46/50 patients (92%). The calculated average TI increase of 2.3 ± 0.5 ms/min obtained in the first fixed TI group was incorporated in the second dynamic TI group and led to a significant decrease of 72% in the mean blood pool signal intensity compared with the fixed TI group (P < 0.001). Overall image quality (P = 0.02), observer confidence (P = 0.02), and scar demarcation (P = 0.01) significantly improved using a dynamic TI.
CONCLUSIONS: A steadily increasing dynamic TI improves blood pool suppression for optimized dark-blood contrast and increases observer confidence in free-breathing 3D dark-blood LGE MRI with high isotropic resolution.
引用
- Holtackers RJ, Gommers S, Van De Heyning CM, et al. Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast. Invest Radiol. 2021. PMID: 33273374. doi:10.1097/RLI.0000000000000747
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。