文献速递心血管MR

心脏磁共振T1图及细胞外容积的纹理分析在肥厚型心肌病与高血压性心脏病诊断中与正常对照的比较

Texture analysis applied in T1 maps and extracellular volume obtained using cardiac MRI in the diagnosis of hypertrophic cardiomyopathy and hypertensive heart disease compared with normal controls.
PubMed 文献 · Clin Radiol · 2020-12-04

回顾性纳入66例肥厚型心肌病、39例高血压性心脏病和41例正常对照,评估心脏磁共振T1图及细胞外容积纹理分析鉴别病变与正常对照、以及区分两种心肌病的能力。纹理分析模型区分患者与正常对照的AUC达0.969(T1图)和0.964(细胞外容积),区分肥厚型心肌病与高血压性心脏病的AUC为0.793(T1图)和0.894(细胞外容积);应变参数区分患者与正常对照有效,但仅纵向应变在两种心肌病间有显著差异。

要点

  • T1图纹理分析区分肥厚型心肌病及高血压性心脏病患者与正常对照的AUC为0.969,细胞外容积为0.964。
  • 细胞外容积纹理分析区分肥厚型心肌病与高血压性心脏病的AUC为0.894,优于T1图的0.793。
  • 径向、周向和纵向应变参数可区分患者与正常对照,但仅纵向应变在两种心肌病间有显著差异。

诊断标准与关键数值

  • T1图纹理分析模型区分肥厚型心肌病及高血压性心脏病患者与正常对照的AUC为0.969。
  • 细胞外容积纹理分析模型区分肥厚型心肌病及高血压性心脏病患者与正常对照的AUC为0.964。
  • T1图纹理分析区分肥厚型心肌病与高血压性心脏病的AUC为0.793。
  • 细胞外容积纹理分析区分肥厚型心肌病与高血压性心脏病的AUC为0.894。

临床应用与阅片要点

  • T1图与细胞外容积纹理分析可用于辅助鉴别肥厚心肌与正常心肌。
  • 细胞外容积纹理分析在区分肥厚型心肌病与高血压性心脏病方面较T1图表现出更高的AUC。
  • 应变参数中仅纵向应变在肥厚型心肌病与高血压性心脏病间有显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the potential of texture analysis (TA) applied in T1 maps and extracellular volume (ECV) obtained using cardiac magnetic resonance (CMR) in the diagnosis of hypertrophic cardiomyopathy (HCM) and hypertensive heart disease (HHD) compared with normal controls (NC). Strain parameters were analysed to compare with final TA models.

MATERIALS AND METHODS: This retrospective study included 66 HCM patients, 39 HHD patients, and 41 NC. Step-wise dimension reduction and feature selection were performed by reproducibility, machine learning, collinearity, and multivariable regression analysis to select the texture features that enable diagnosis of and differentiation between HCM and HHD. Strain parameters were calculated by short-axis and three long-axis cine sequences.

RESULTS: Independent features in T1 maps and ECV analysis allowed for the differentiation between patients (HCM and HHD) and NC. Of the best-calculated model, the areas under the receiver operating curve (AUCs) were as follows: 0.969 for T1 map and 0.964 for ECV. To distinguish HCM from HHD, two independent features were screened out for both T1 and ECV maps. The AUCs were as follows: 0.793 for T1 map and 0.894 for ECV. Radial, circumferential, and longitudinal strain parameters could differentiate patients from NC, but only longitudinal strain parameters was significantly different between HCM and HHD.

CONCLUSIONS: Texture analysis of T1 maps and ECV shows high accuracy in differentiating hypertrophic myocardium from NC, and HCM from HHD. Strain parameters are able to demonstrate the difference between patients and NC, but were less impressive in differentiating HCM and HHD.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Shi RY, Wu R, An DL, et al. Texture analysis applied in T1 maps and extracellular volume obtained using cardiac MRI in the diagnosis of hypertrophic cardiomyopathy and hypertensive heart disease compared with normal controls. Clin Radiol. 2020. PMID: 33272531. doi:10.1016/j.crad.2020.11.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。