文献速递心血管MR

非增强T1 mapping影像组学对急性ST段抬高型心肌梗死心肌损伤的诊断与预测效能

Radiomics of Non-Contrast-Enhanced T1 Mapping: Diagnostic and Predictive Performance for Myocardial Injury in Acute ST-Segment-Elevation Myocardial Infarction.
PubMed 文献 · Korean J Radiol · 2020-11-30

本研究纳入68例急性ST段抬高型心肌梗死患者,于经皮冠状动脉介入治疗后行3T心脏磁共振检查,从非增强T1 mapping提取影像组学特征。联合影像组学标签与T1值诊断微血管阻塞的AUC在训练集为0.88、测试集为0.86,均高于单用T1值;联合模型预测6个月左室纵向收缩心肌收缩力恢复的AUC在训练集为0.76、测试集为0.77,亦高于单用T1值。

要点

  • 非增强T1 mapping影像组学联合T1值可提高急性ST段抬高型心肌梗死后微血管阻塞的诊断效能。
  • 影像组学对6个月左室纵向收缩心肌收缩力恢复具有增量预测价值。
  • 急性期103/1088个(9.5%)节段见微血管阻塞,557/1088个(51.2%)节段见心肌梗死。

关键影像表现/征象

  • 急性期心脏磁共振共分析1088个节段,其中103个(9.5%)节段显示微血管阻塞,557个(51.2%)节段显示心肌梗死。
  • 6个月随访分析共纳入640个节段,其中160个(25.0%)节段显示左室纵向收缩心肌收缩力良好恢复。

诊断标准与关键数值

  • 联合影像组学标签与T1值诊断微血管阻塞的AUC在训练集为0.88、测试集为0.86,单用T1值分别为0.72和0.71(训练集p=0.031,测试集p002,原文如此)。
  • 联合影像组学标签与T1值预测左室纵向收缩心肌收缩力恢复的AUC在训练集为0.76、测试集为0.77,单用T1值分别为0.55和0.60(训练集与测试集均p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of texture analysis on non-contrast-enhanced T1 maps of cardiac magnetic resonance (CMR) imaging for the diagnosis of myocardial injury in acute myocardial infarction (MI).

MATERIALS AND METHODS: This study included 68 patients (57 males and 11 females; mean age, 55.7 ± 10.5 years) with acute ST-segment-elevation MI who had undergone 3T CMR after a percutaneous coronary intervention. Forty patients of them also underwent a 6-month follow-up CMR. The CMR protocol included T2-weighted imaging, T1 mapping, rest first-pass perfusion, and late gadolinium enhancement. Radiomics features were extracted from the T1 maps using open-source software. Radiomics signatures were constructed with the selected strongest features to evaluate the myocardial injury severity and predict the recovery of left ventricular (LV) longitudinal systolic myocardial contractility.

RESULTS: A total of 1088 segments of the acute CMR images were analyzed; 103 (9.5%) segments showed microvascular obstruction (MVO), and 557 (51.2%) segments showed MI. A total of 640 segments were included in the 6-month follow-up analysis, of which 160 (25.0%) segments showed favorable recovery of LV longitudinal systolic myocardial contractility. Combined radiomics signature and T1 values resulted in a higher diagnostic performance for MVO compared to T1 values alone (area under the curve [AUC] in the training set; 0.88, 0.72, p = 0.031: AUC in the test set; 0.86, 0.71, p002). Combined radiomics signature and T1 values also provided a higher predictive value for LV longitudinal systolic myocardial contractility recovery compared to T1 values (AUC in the training set; 0.76, 0.55, p < 0.001: AUC in the test set; 0.77, 0.60, p < 0.001).

CONCLUSION: The combination of radiomics of non-contrast-enhanced T1 mapping and T1 values could provide higher diagnostic accuracy for MVO. Radiomics also provides incremental value in the prediction of LV longitudinal systolic myocardial contractility at six months.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Ma Q, Ma Y, Yu T, et al. Radiomics of Non-Contrast-Enhanced T1 Mapping: Diagnostic and Predictive Performance for Myocardial Injury in Acute ST-Segment-Elevation Myocardial Infarction. Korean J Radiol. 2020. PMID: 33289360. doi:10.3348/kjr.2019.0969

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。