左心发育不良复合征胎儿双心室循环的产前超声心动图预测因素
本研究分析2004至2017年间51例18-26周及27-36周妊娠的左心发育不良复合征胎儿超声心动图,44例成功实现双心室循环。多因素分析显示卵圆孔右向左/双向血流及较高二尖瓣环Z评分与双心室循环相关;双向或左向右卵圆孔血流、左心室长度Z评分<-2.4及二尖瓣Z评分<-4.5可正确预测80%未实现双心室循环病例。
要点
- 卵圆孔血流方向为右向左或双向、二尖瓣环Z评分较高提示胎儿期更可能实现双心室循环。
- 双向或左向右卵圆孔血流、左心室长度Z评分<-2.4、二尖瓣Z评分<-4.5可正确预测80%单心室转归病例。
- 实现双心室循环者远期可能出现二尖瓣狭窄和主动脉瓣下狭窄,需长期随访。
核心结论
- 左心发育不良复合征胎儿中双心室循环常见,较高的二尖瓣环和左心室长度Z评分及卵圆孔右向左血流是双心室循环的重要预测因素。
- 实现双心室循环者的远期后遗症可能包括二尖瓣狭窄和主动脉瓣下狭窄。
研究设计与样本
- 研究纳入2004至2017年间18-26周和27-36周妊娠的左心发育不良复合征胎儿超声心动图进行分析。
- 共纳入51例,主要结局为成功实现双心室循环(第1组),第2组包括单心室姑息手术、死亡或移植。
- 对18-26周和27-36周数据行单因素分析,仅对27-36周数据行多因素logistic回归。
关键影像表现/征象
- 卵圆孔血流方向为右向左或双向、二尖瓣环Z评分较高与成功双心室循环相关(单因素和多因素分析均显示)。
诊断标准与关键数值
- 双向或左向右卵圆孔血流、左心室长度Z评分<-2.4及二尖瓣Z评分<-4.5可正确预测80%的第2组病例。
临床应用与阅片要点
- 产前超声评估左心发育不良复合征时,应关注卵圆孔血流方向及二尖瓣环、左心室长度Z评分以预测出生后循环转归。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To determine which echocardiographic features of hypoplastic left heart complex (HLHC) in the fetal period are predictive of biventricular (BV) circulation and to evaluate the long-term outcome of patients with HLHC, including rates of mortality, reintervention and development of further cardiac disease.
METHODS: Echocardiograms of fetuses with HLHC obtained at 18-26 weeks and 27-36 weeks' gestation between 2004 and 2017 were included in the analysis. The primary outcome was successful BV circulation (Group 1). Group 2 included patients with single-ventricle palliation, death or transplant. Univariate analysis was performed on data obtained at 18-26 and 27-36 weeks and multivariate logistic regression was performed on data obtained at 27-36 weeks only.
RESULTS: Of the 51 included cases, 44 achieved successful BV circulation (Group 1) and seven did not (Group 2). Right-to-left/bidirectional foramen ovale (FO) flow and a higher mitral valve (MV) annulus Z-score were associated with successful BV circulation on both univariate and multivariate analysis. Bidirectional or left-to-right FO flow, left ventricular length (LVL) Z-score of < -2.4 and a MV Z-score of < -4.5 correctly predicted 80% of Group 2 cases. Late follow-up was available for 41 patients. There were two late deaths in Group 2. Thirteen patients in Group 1 required reintervention, 12 developed mitral stenosis and five developed isolated subaortic stenosis.
CONCLUSIONS: BV circulation is common in fetuses with HLHC. Higher MV annulus and LVL Z-scores and right to left direction of FO flow are important predictors of BV circulation. Long-term sequelae in those with BV circulation may include mitral and subaortic stenosis. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Haberer K, Fruitman D, Power A, et al. Fetal echocardiographic predictors of biventricular circulation in hypoplastic left heart complex. Ultrasound Obstet Gynecol. 2021. PMID: 33270293. doi:10.1002/uog.23558
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。