在无呼吸症状队列中评估稳健CT衍生通气与肺功能检查的相关性
研究分析NORM数据集中77例无呼吸症状白种人的CT与肺功能检查,用稳健积分雅可比公式法生成CT通气成像并估算总肺容量,与肺功能检查测得的总肺容量呈良好相关,调整年龄、身高、吸烟和CT异常后相关性减弱。
要点
- 无呼吸症状者中,CT通气成像估算总肺容量与肺功能检查总肺容量呈良好相关。
- 调整年龄、身高、吸烟和CT异常后,男女相关性均减弱。
- 高分辨率CT正常者中,CT通气成像视觉检查仍可发现功能缺陷。
核心结论
- 在经验证的无呼吸症状队列中,积分雅可比公式法计算的CT通气成像与同期肺功能检查呈良好相关。
研究设计与样本
- 研究分析NORM数据集(clinicaltrials.gov NCT00848406)中77例白种参与者的CT扫描和肺功能检查。
- CT通气成像采用稳健积分雅可比公式法生成,并据此计算估算总肺容量。
- 计算肺功能检查与积分雅可比公式法估算总肺容量之间的偏倚校正皮尔逊相关系数。
关键影像表现/征象
- 视觉检查CT通气成像发现,部分参与者存在功能缺陷,尽管所有参与者高分辨率CT均正常。
诊断标准与关键数值
- 积分雅可比公式法与肺功能检查测得总肺容量的相关性:男性0.657(95%CI 0.438-0.797),女性0.667(95%CI 0.416-0.817)。
- 调整年龄、身高、吸烟和CT扫描异常后,相关性减弱:男性0.432(95%CI 0.129-0.655),女性0.540(95%CI 0.207-0.753)。
临床应用与阅片要点
- 积分雅可比公式法计算的CT通气成像整体数值稳健且与肺功能检查一致,支持其作为在容积非增强CT上提供高低功能区时空评估方法的潜力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate CT-ventilation imaging (CTVI) within a well-characterized, healthy cohort with no respiratory symptoms and examine the correlation between CTVI and concurrent pulmonary function test (PFT).
METHODS: CT scans and PFTs from 77 Caucasian participants in the NORM dataset (clinicaltrials.gov NCT00848406) were analyzed. CTVI was generated using the robust Integrated Jacobian Formulation (IJF) method. IJF estimated total lung capacity (TLC) was computed from CTVI. Bias-adjusted Pearson's correlation between PFT and IJF-based TLC was computed.
RESULTS: IJF- and PFT-measured TLC showed a good correlation for both males and females [males: 0.657, 95% CI (0.438-0.797); females: 0.667, 95% CI (0.416-0.817)]. When adjusting for age, height, smoking, and abnormal CT scan, correlation moderated [males: 0.432, 95% CI (0.129-0.655); females: 0.540, 95% CI (0.207-0.753)]. Visual inspection of CTVI revealed participants who had functional defects, despite the fact that all participant had normal high-resolution CT scan.
CONCLUSION: In this study, we demonstrate that IJF computed CTVI has good correlation with concurrent PFT in a well-validated patient cohort with no respiratory symptoms.
ADVANCES IN KNOWLEDGE: IJF-computed CTVI's overall numerical robustness and consistency with PFT support its potential as a method for providing spatiotemporal assessment of high and low function areas on volumetric non-contrast CT scan.
引用
- Nair GB, Galban CJ, Al-Katib S, et al. An assessment of the correlation between robust CT-derived ventilation and pulmonary function test in a cohort with no respiratory symptoms. Br J Radiol. 2020. PMID: 33320729. doi:10.1259/bjr.20201218
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。