最小强度投影在COVID-19患者胸部CT中的价值
这项多国回顾性研究分析185例疑似COVID-19患者的胸部CT,比较最小强度投影(MinIP)与标准横断面及多平面重组(MPR)对磨玻璃影(GGO)的评估价值。MinIP的敏感度(99.9% vs 95.6%)、特异度(95.8% vs 86.1%)和准确率(99.1% vs 93.8%)均显著高于MPR,放射科医生和临床医生对MinIP的诊断信心、图像质量和主观时间效率评分也更高。结论认为MinIP可改善COVID-19胸部CT评估,可能适合常规应用。
要点
- MinIP评估GGO的敏感度99.9%、特异度95.8%、准确率99.1%,均显著高于标准MPR系列。
- 放射科医生对MinIP的诊断信心、GGO与正常肺实质对比及主观时间效率评分中位数均高于MPR。
- 临床医生对MinIP在COVID-19评估、GGO图像质量和临床常规主观时间效率方面的偏好评分中位数均高于MPR。
核心结论
- MinIP重建较标准图像可改善胸部CT对COVID-19的评估,可能适合常规应用。
研究设计与样本
- 多国回顾性研究,纳入185例疑似COVID-19患者的胸部CT,由6名放射科医生和5名临床医生进行评估。
- 以参考标准确认149例CT存在肺部GGO,比较MinIP与标准横断面及MPR系列的诊断准确率、诊断信心、GGO图像质量和主观时间效率。
关键影像表现/征象
- MinIP重建可更准确显示肺部GGO,GGO与未受累肺实质的对比评分中位数MinIP为5.00、MPR为4.00(P < .001)。
诊断标准与关键数值
- MinIP评估GGO的敏感度99.9%、特异度95.8%、准确率99.1%,标准MPR系列分别为95.6%、86.1%、93.8%。
- 放射科医生对MinIP的诊断信心评分中位数5.00、MPR为4.00;图像质量评分中位数均为4.00;主观时间效率评分中位数MinIP为5.00、MPR为4.00(均P < .001)。
- 临床医生对MinIP的COVID-19评估、GGO图像质量和临床常规主观时间效率评分中位数均为5.00,MPR均为3.00。
临床应用与阅片要点
- 作者认为MinIP重建可改善胸部CT对COVID-19的评估,可能适合常规应用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate whether minimum intensity projection (MinIP) reconstructions enable more accurate depiction of pulmonary ground-glass opacity (GGO) compared to standard transverse sections and multiplanar reformat (MPR) series in patients with suspected coronavirus disease 2019 (COVID-19).
METHOD: In this multinational study, chest CT scans of 185 patients were retrospectively analyzed. Diagnostic accuracy, diagnostic confidence, image quality regarding the assessment of GGO, as well as subjective time-efficiency of MinIP and standard MPR series were analyzed based on the assessment of six radiologists. In addition, the suitability for COVID-19 evaluation, image quality regarding GGO and subjective time-efficiency in clinical routine was assessed by five clinicians.
RESULTS: The reference standard revealed a total of 149 CT scans with pulmonary GGO. MinIP reconstructions yielded significantly higher sensitivity (99.9 % vs 95.6 %), specificity (95.8 % vs 86.1 %) and accuracy (99.1 % vs 93.8 %) for assessing of GGO compared with standard MPR series. MinIP reconstructions achieved significantly higher ratings by radiologists concerning diagnostic confidence (medians, 5.00 vs 4.00), image quality (medians, 4.00 vs 4.00), contrast between GGO and unaffected lung parenchyma (medians, 5.00 vs 4.00) as well as subjective time-efficiency (medians, 5.00 vs 4.00) compared with MPR-series (all P < .001). Clinicians preferred MinIP reconstructions for COVID-19 assessment (medians, 5.00 vs 3.00), image quality regarding GGO (medians, 5.00 vs 3.00) and subjective time-efficiency in clinical routine (medians, 5.00 vs 3.00).
CONCLUSIONS: MinIP reconstructions improve the assessment of COVID-19 in chest CT compared to standard images and may be suitable for routine application.
引用
- Booz C, Vogl TJ, Joseph Schoepf U, et al. Value of minimum intensity projections for chest CT in COVID-19 patients. Eur J Radiol. 2020. PMID: 33360269. doi:10.1016/j.ejrad.2020.109478
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。