文献速递胸部介入CT

CT引导下空心针活检对薄壁空洞性肺病变的诊断准确性

Diagnostic Accuracy of CT-Guided Core Needle Biopsy for Thin-Walled Cavitary Pulmonary Lesions.
PubMed 文献 · AJR Am J Roentgenol · 2020-12-09

回顾性研究评估32例薄壁空洞性肺病变(壁厚<5 mm)行CT引导下空心针活检的诊断准确性及并发症。活检诊断敏感度89.5%、特异度100%、准确率93.3%;气胸7例、需置管1例、轻度肺实质出血15例、咯血1例。作者认为该技术对薄壁空洞活检有用且准确。

要点

  • 薄壁空洞(壁厚<5 mm)CT引导空心针活检诊断准确率93.3%,敏感度89.5%、特异度100%。
  • 并发症以轻度气胸和轻度肺实质出血为主,需置管的气胸仅1例。
  • 壁厚、空洞大小及病灶深度对准确性、敏感度、特异度无统计学差异。

核心结论

  • CT引导下空心针活检是薄壁空洞性肺病变有用且准确的诊断技术。

研究设计与样本

  • 回顾性研究,纳入30例患者共32次CT引导下空心针活检,病变壁厚<5 mm。
  • 以手术或临床随访的最终诊断作为参考标准,比较活检的诊断准确性、敏感度和特异度。

关键影像表现/征象

  • 最终诊断恶性19例、良性11例;2例活检结果不确定(炭末纤维化及局灶性间质增厚)被排除。

诊断标准与关键数值

  • 薄壁空洞活检的敏感度89.5%、特异度100%、诊断准确率93.3%。
  • 壁厚、空洞大小、病灶深度各亚组间准确性、敏感度、特异度无统计学差异。

临床应用与阅片要点

  • 活检后即刻胸部CT显示轻度气胸7例、中重度气胸需置胸管1例。
  • 活检后CT显示轻度肺实质出血15例、咯血1例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this article is to evaluate the accuracy of and complications with CT-guided percutaneous core needle biopsy (CNB) of thin-walled cavitary pulmonary lesions. MATERIALS AND METHODS. This retrospective study involved 32 CNBs in 30 patients who had thin-walled cavitary pulmonary lesions (wall thickness < 5 mm) and underwent CT-guided CNB. After the 30 patient records were evaluated for the diagnostic accuracy, sensitivity, and specificity of CT-guided CNB, the results were compared with the final diagnosis after surgery or clinical follow-up. Each patient was reviewed for complications including pneumothorax, thoracotomy tube insertion, hemorrhage, and hemoptysis. RESULTS. The final diagnosis indicated 19 malignant and 11 benign lesions. Two lesions with indeterminate biopsy results (anthracofibrosis and focal interstitial thickening) were excluded. The sensitivity, specificity, and diagnostic accuracy of thin-walled cavities were 89.5%, 100%, and 93.3%, respectively. There were no statistical differences in the accuracy, sensitivity, or specificity according to wall thickness, cavity size, or lesion depth. Chest CT immediately after biopsy revealed mild pneumothorax in seven patients and moderate to severe pneumothorax requiring placement of a thoracotomy tube in one patient. CT after biopsy indicated mild parenchymal hemorrhage in 15 patients and hemoptysis in one patient. CONCLUSION. CT-guided CNB is a useful and accurate diagnostic technique for biopsy of a pulmonary thin-walled cavity.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Shin KE, Park JS, Lee JW, et al. Diagnostic Accuracy of CT-Guided Core Needle Biopsy for Thin-Walled Cavitary Pulmonary Lesions. AJR Am J Roentgenol. 2020. PMID: 33295816. doi:10.2214/AJR.20.22780

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。