单次激发平面回波成像与单次激发快速自旋回波扩散加权成像在眼黑色素瘤患者眼眶检查中的对比

Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma.
PubMed 文献 · Br J Radiol · 2020-12-22

本研究前瞻性纳入50例葡萄膜黑色素瘤患者,对比眼眶单次激发平面回波扩散加权成像(ssEPI-DWI)与单次激发快速自旋回波扩散加权成像(ssTSE-DWI)的图像质量。结果显示ssTSE-DWI几何变形和伪影更少、分辨率和整体质量更好,但ssEPI-DWI对眼内肿块边界的显示更佳。作者认为ssTSE-DWI可作为ssEPI-DWI的替代方案用于眼眶扩散成像。

要点

  • ssTSE-DWI较ssEPI-DWI几何变形和伪影更少、分辨率和整体质量更优。
  • ssEPI-DWI对眼内肿块的边界显示优于ssTSE-DWI。
  • ssEPI-DWI的颞叶皮层SNR和CNR较低,但黑色素瘤的SNR和CNR较高。

关键影像表现/征象

  • ssEPI-DWI的变形率高于ssTSE-DWI(p < 0.001)。
  • ssEPI-DWI几何变形和伪影更常见(p < 0.001)。
  • ssTSE-DWI的分辨率(p ≤ 0.013)和整体质量(p < 0.001)优于ssEPI-DWI。
  • 眼内肿块边界在ssEPI-DWI上显示更好(p ≤ 0.002)。

诊断标准与关键数值

  • ssEPI-DWI颞叶皮层SNR和CNR低于ssTSE-DWI(p ≤ 0.004)。
  • ssEPI-DWI黑色素瘤SNR和CNR高于ssTSE-DWI(p ≤ 0.037)。
  • T1与T2信号强度呈负相关(r = -0.369,p ≤ 0.008)。
  • T2与DWI信号强度呈正相关:ssEPI-DWI r = 0.686(p < 0.001),ssTSE-DWI r = 0.747(p < 0.001)。

临床应用与阅片要点

  • 作者认为ssTSE-DWI可作为ssEPI-DWI的替代方案用于眼眶扩散加权成像。
  • 阅片时需注意ssEPI-DWI磁敏感伪影和几何变形较多,可能影响眼眶结构的评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Diffusion weighted imaging (DWI) has become important for orbital imaging. However, the echoplanar imaging (EPI) DWI has inherent obstacles due to susceptibility to magnetic field inhomogeneities. We conducted a comparative study assessing the image quality of orbits in a patient cohort with uveal melanoma (UM). We hypothesized that single shot turbo spin echo (ssTSE) DWI would have better image quality in terms of less distortion and artifacts and yield better tissue evaluation compared to ssEPI-DWI.

METHODS: ssEPI-DWI and ssTSE-DWI of orbits were obtained from 50 patients with uveal melanoma who were prospectively enrolled in the study. Distortion ratio (DR), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), diffusion signal properties, and apparent diffusion coefficient (ADC) values were collected and compared between ssEPI-DWI and ssTSE-DWI. Two reviewers evaluated and compared the geometric distortion, susceptibility and ghosting artifacts, resolution, demarcation of ocular mass, and overall quality.

RESULTS: A higher DR was found in ssEPI-DWI compared to ssTSE-DWI (p < 0.001). SNR and CNR were lower for the temporal lobe cortex (p ≤ 0.004), but higher for melanoma in ssEPI-DWI than ssTSE-DWI (p ≤ 0.037). Geometric distortion and artifacts were more common in ssEPI-DWI (p < 0.001). Resolution (p ≤ 0.013) and overall quality (p < 0.001) were better in ssTSE-DWI. Ocular masses were demarcated better on ssEPI-DWI (p ≤ 0.002). Significant negative correlations between T1 and T2 signal intensities (r = -0.369, p ≤ 0.008) and positive correlations between T2 and both DWI signal intensities (r = 0.686 and p < 0.001 for ssEPI-DWI, r = 0.747 and p < 0.001 for ssTSE-DWI) were revealed.

CONCLUSION: With less geometric distortion and susceptibility artifacts, better resolution, and overall quality, ssTSE-DWI can serve as an alternative to ssEPI-DWI for orbital DWI.

ADVANCES IN KNOWLEDGE: ssTSE-DWI can be a better alternative of diffusion imaging of orbits with less susceptibility artifact and geometric distortion compared to ssEPI-DWI.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Gumeler E, Parlak S, Yazici G, et al. Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma. Br J Radiol. 2020. PMID: 33264035. doi:10.1259/bjr.20200825

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。