高空间分辨率3D-QALAS联合压缩感知加速各向同性多参数成像:体模、志愿者与患者研究

Accelerated Isotropic Multiparametric Imaging by High Spatial Resolution 3D-QALAS With Compressed Sensing: A Phantom, Volunteer, and Patient Study.
PubMed 文献 · Invest Radiol · 2021-01-01

本研究开发了基于3D-QALAS联合压缩感知(CS)的加速多参数MRI方法,在体模、10名健康志愿者和12名多发性硬化患者中评估CS对定量成像、组织分割及合成图像质量的影响。CS将扫描时间从11分11秒缩短至5分56秒,定量值、组织分割及合成图像质量与无CS时保持高度一致,图像质量无显著差异。

要点

  • 3D-QALAS联合CS将全脑多参数扫描时间从11:11缩短至5:56,定量T1、T2、PD值及组织分割与无CS高度一致(R²=0.967-1.000)。
  • 合成对比加权图像的整体图像质量在CS与无CS间无显著差异(P=0.17-0.99),可用于临床阅片。
  • 多发性硬化斑块与对侧正常表现白质的定量值在CS下保持高度线性,支持CS用于定量随访。

核心结论

  • 基于3D-QALAS的全脑多参数成像可使用压缩感知加速,同时保持组织定量值、组织分割和合成图像质量。

研究设计与样本

  • 研究类型为体模、志愿者与患者研究,纳入含标准化T1、T2、质子密度值的MRI系统体模、10名健康志愿者和12名多发性硬化患者。
  • 所有受试者均行3D-QALAS序列(有和无压缩感知)及常规对比加权成像,有和无CS的扫描时间分别为5:56和11:11。
  • 健康志愿者基于测得的T1、T2、PD进行脑容量分析和髓鞘估计;多发性硬化患者测量斑块和对侧正常表现白质的平均T1、T2、PD及髓鞘含量。
  • 采用简单线性回归和Bland-Altman分析比较有和无CS数据集获得的各指标;由2名神经放射科医生以盲法、病例对照随机阅读方式比较合成与常规对比加权图像的整体图像质量和结构勾画。

关键影像表现/征象

  • 体模和志愿者在有和无CS条件下测得的T1、T2、PD值均呈现很强的线性(R²=0.9901-1.000)。
  • 有和无CS获得的组织分割也具有高度线性(R²=0.987-0.999)。
  • CS获得的斑块和正常表现白质定量组织值与无CS高度线性(R²=0.967-1.000)。

临床应用与阅片要点

  • 本研究显示压缩感知可在保持定量值和合成图像质量的前提下加速3D-QALAS全脑多参数成像,但原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aims of this study were to develop an accelerated multiparametric magnetic resonance imaging method based on 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) combined with compressed sensing (CS) and to evaluate the effect of CS on the quantitative mapping, tissue segmentation, and quality of synthetic images.

MATERIALS AND METHODS: A magnetic resonance imaging system phantom, containing multiple compartments with standardized T1, T2, and proton density (PD) values; 10 healthy volunteers; and 12 patients with multiple sclerosis were scanned using the 3D-QALAS sequence with and without CS and conventional contrast-weighted imaging. The scan times of 3D-QALAS with and without CS were 5:56 and 11:11, respectively. For healthy volunteers, brain volumetry and myelin estimation were performed based on the measured T1, T2, and PD. For patients with multiple sclerosis, the mean T1, T2, PD, and the amount of myelin in plaques and contralateral normal-appearing white matter (NAWM) were measured. Simple linear regression analysis and Bland-Altman analysis were performed for each metric obtained from the datasets with and without CS. To compare overall image quality and structural delineations on synthetic and conventional contrast-weighted images, case-control randomized reading sessions were performed by 2 neuroradiologists in a blinded manner.

RESULTS: The linearity of both phantom and volunteer measurements in T1, T2, and PD values obtained with and without CS was very strong (R2 = 0.9901-1.000). The tissue segmentation obtained with and without CS also had high linearity (R2 = 0.987-0.999). The quantitative tissue values of the plaques and NAWM obtained with CS showed high linearity with those without CS (R2 = 0.967-1.000). There were no significant differences in overall image quality between synthetic contrast-weighted images obtained with and without CS (P = 0.17-0.99).

CONCLUSIONS: Multiparametric imaging of the whole brain based on 3D-QALAS can be accelerated using CS while preserving tissue quantitative values, tissue segmentation, and quality of synthetic images.

来源:Invest Radiol,查看原文。版权归原作者所有。