三维T1-SPACE与DSA评估颅内支架内再狭窄的比较

Comparison of 3D T1-SPACE and DSA in evaluation of intracranial in-stent restenosis.
PubMed 文献 · Br J Radiol · 2020-12-01

前瞻性纳入15例颅内动脉狭窄支架置入后6-8个月患者,同期行DSA与3D T1-SPACE检查评估狭窄程度及血管壁强化。3D T1-SPACE与DSA测得的狭窄程度一致性高(Pearson相关系数0.959,P<0.05),4例支架内再狭窄均显示明显强化;3D T1-SPACE可作为无创检测支架内再狭窄的可选方法。

要点

  • 3D T1-SPACE与DSA测得的支架术后狭窄程度一致性高,Pearson相关系数0.959(P<0.05)。
  • 支架内再狭窄的4例病变在3D T1-SPACE上均表现为明显强化。
  • 3D T1-SPACE可作为无创随访颅内支架置入后支架内再狭窄的可选方法。

核心结论

  • 3D T1-SPACE作为无创影像方法,在测量颅内支架置入后狭窄程度方面与DSA一致性高,可能作为检测支架内再狭窄的可选方法。

研究设计与样本

  • 前瞻性纳入15例颅内动脉狭窄支架置入后6-8个月的患者,同期行DSA和3D T1-SPACE成像评估狭窄程度及血管壁强化。
  • 使用Enterprise支架8枚、Wingspan支架7枚。
  • 采用Bland-Altman图评估两种方法的一致性,并计算Pearson相关系数衡量线性相关。

关键影像表现/征象

  • 支架内再狭窄的4例病变在3D T1-SPACE上均显示明显强化。

诊断标准与关键数值

  • 随访DSA(6-8个月)显示狭窄程度为40%(范围30-72%),15个病变中4个(26.7%)发生支架内再狭窄。
  • 3D T1-SPACE评估的狭窄程度为35%(范围30-75%)。
  • 两种方法的Pearson相关系数为0.959(P<0.05),Bland-Altman图显示所有数据点均在一致性界限内(平均值±1.96标准差)。

临床应用与阅片要点

  • 3D T1-SPACE可作为无创随访颅内支架置入后狭窄程度及检测支架内再狭窄的可选方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: In-stent restenosis (ISR) after stenting for intracranial stenosis is a significant issue. This study aimed to evaluate the usefulness of the 3D T1-SPACE technique in the follow-up of patients after stent implantation.

METHODS: Fifteen patients with intracranial arterial stenosis were prospectively enrolled 6-8 months after stenting. Digital subtraction angiography (DSA) and 3D T1-SPACE imaging were performed to evaluate the degree of stenosis and the enhancement of the vessel wall. Bland-Altman plots were used to assess the agreement between the two imaging methods, and the Pearson correlation coefficient was calculated as a measure of the linear correlation.

RESULTS: Eight Enterprise stents and seven Wingspan stents were used in 15 patients. The follow-up DSA after 6-8 months showed that the degree of stenosis was 40% (range, 30-72%), and ISR occurred in 4 of 15 (26.7%) lesions. The degree of stenosis assessed using the 3D T1-SPACE imaging technique was 35% (range, 30-75%). All four patients with ISR demonstrated significant enhancement. The Pearson correlation coefficient between the two methods was 0.959 (p < 0.05), and the Bland-Altman plot showed that all data points were within the consistency limits ([Formula: see text] ± 1.96 s).

CONCLUSION: As a non-invasive imaging modality, 3D T1-SPACE showed great consistency with DSA in measuring the degree of stenosis after intracranial stenting. It may be used as an optional method for detecting ISR.

ADVANCES IN KNOWLEDGE: This study evaluated the usefulness of 3D T1-SPACE technique in the follow-up of patients after stent implantation, which could be used as an optional and non-invasive method in detection of in-stent restenosis.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Shao Q, Li Q, Wu Q, et al. Comparison of 3D T1-SPACE and DSA in evaluation of intracranial in-stent restenosis. Br J Radiol. 2020. PMID: 33259233. doi:10.1259/bjr.20190950

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。