鉴别高级别胶质瘤复发与假性进展:扩散峰度成像与扩散张量成像的比较
本研究纳入40例高级别胶质瘤术后放化疗后6个月内出现新强化病灶的患者(24例复发、16例假性进展),均经再次手术或活检病理分组,比较DKI与DTI参数的鉴别效能。复发组强化病灶的相对平均峰度(rMK)显著高于假性进展组、相对平均扩散率(rMD)显著低于假性进展组,rMK的AUC为0.914、rMD为0.760,两者差异有统计学意义(P=0.030)。结论认为DKI鉴别效能优于DTI,rMK似乎是最佳独立预测因子。
要点
- 强化病灶rMK在复发组显著高于假性进展组(P<0.001),rMD显著低于假性进展组(P=0.006)。
- rMK鉴别复发与假性进展的AUC为0.914,rMD为0.760,两者差异有统计学意义(P=0.030)。
- 瘤周水肿区rMK在复发组显著高于假性进展组、rMD显著低于假性进展组(P<0.001、P=0.005)。
关键影像表现/征象
- 复发组强化病灶rMK显著高于假性进展组(P<0.001),rMD显著低于假性进展组(P=0.006)。
- 复发组瘤周水肿区rMK显著高于假性进展组(P<0.001),rMD显著低于假性进展组(P=0.005)。
诊断标准与关键数值
- 强化病灶rMK鉴别复发与假性进展的AUC为0.914,rMD的AUC为0.760,两者差异有统计学意义(P=0.030)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the diagnostic value of DKI and DTI in differentiation of high-grade glioma recurrence and pseudoprogression (PsP).
METHOD: Forty patients with high-grade gliomas who exhibited new enhancing lesions (24 high-grade glioma recurrence and 16 PsP) within 6 months after surgery followed by completion of chemoradiation therapy. All patients underwent repeat surgery or biopsy after routine MRI and DKI (including DTI). They were histologically classified into high-grade glioma recurrence and PsP groups. DKI (mean kurtosis [MK], axial kurtosis [Ka], and radial kurtosis [Kr]) and DTI (mean diffusivity [MD] and fractional anisotropy [FA]) parameters in the enhancing lesions and in the perilesional edema were measured. Inter-group differences between high-grade glioma recurrence and PsP were compared using the Mann-Whitney U test The receiver operating characteristic (ROC) curve was used to assess differential diagnostic efficacy of each parameter, and Z-scores were used to compare the value between DKI and DTI.
RESULTS: Relative MK (rMK) was significantly higher and relative MD (rMD) was significantly lower in the enhancing lesions of high-grade glioma recurrence compared to PsP (P < 0.001, P = 0.006, respectively). The AUC was 0.914 for rMK and 0.760 for rMD, and this difference was significant (P = 0.030). In the perilesional edema, rMK values were significantly higher and rMD values were significantly lower in high-grade glioma recurrence compared to PsP (P < 0.001, P = 0.005).
CONCLUSIONS: DKI had superior performance in differentiating high-grade glioma recurrence from PsP, and rMK appeared to be the best independent predictor.
引用
- Wu XF, Liang X, Wang XC, et al. Differentiating high-grade glioma recurrence from pseudoprogression: Comparing diffusion kurtosis imaging and diffusion tensor imaging. Eur J Radiol. 2020. PMID: 33341429. doi:10.1016/j.ejrad.2020.109445
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。