文献速递神经头颈MR

薄层垂体MRI联合深度学习重建:术后诊断效能评估

Thin-Slice Pituitary MRI with Deep Learning-based Reconstruction: Diagnostic Performance in a Postoperative Setting.
PubMed 文献 · Radiology · 2020-11-03

单机构回顾性研究纳入65例垂体腺瘤术后患者,比较3mm层厚MRI、1mm层厚MRI及1mm层厚联合深度学习重建(DLR)MRI对残留肿瘤和海绵窦侵犯的诊断效能。1mm MRI+DLR诊断海绵窦侵犯的AUC(0.95-0.98)高于3mm MRI(0.83-0.87),诊断残留肿瘤的AUC(0.89-0.92)与3mm MRI(0.85-0.89)相当。

要点

  • 1mm MRI+DLR诊断海绵窦侵犯的AUC为0.95-0.98,高于3mm MRI的0.83-0.87(P ≤ .02)。
  • 1mm MRI+DLR诊断残留肿瘤的AUC为0.89-0.92,与3mm MRI的0.85-0.89相当(P ≥ .09)。
  • 1mm MRI+DLR额外诊断出20例残留肿瘤和14例海绵窦侵犯,这些病例在3mm MRI上未被诊断。

关键影像表现/征象

  • 1mm MRI+DLR诊断出20例残留肿瘤,这些病例在3mm MRI上未被诊断。
  • 1mm MRI+DLR诊断出14例海绵窦侵犯,这些病例在3mm MRI上未被诊断。

诊断标准与关键数值

  • 残留肿瘤:1mm MRI+DLR的AUC为0.89-0.92,3mm MRI的AUC为0.85-0.89(P ≥ .09)。
  • 海绵窦侵犯:1mm MRI+DLR的AUC为0.95-0.98,3mm MRI的AUC为0.83-0.87(P ≤ .02)。
  • 常规1mm MRI的AUC为0.82-0.83,与3mm MRI的AUC 0.83-0.87相当(P ≥ .38)。

临床应用与阅片要点

  • 1mm MRI+DLR可提高海绵窦侵犯的检出,并额外发现3mm MRI未显示的残留肿瘤和海绵窦侵犯。
  • 参考标准综合了所有可用影像资源、临床病史、实验室检查、手术记录和病理报告。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Achieving high-spatial-resolution pituitary MRI is challenging because of the trade-off between image noise and spatial resolution. Deep learning-based MRI reconstruction enables image denoising with sharp edges and reduced artifacts, which improves the image quality of thin-slice MRI. Purpose To assess the diagnostic performance of 1-mm slice thickness MRI with deep learning-based reconstruction (DLR) (hereafter, 1-mm MRI+DLR) compared with 3-mm slice thickness MRI (hereafter, 3-mm MRI) for identifying residual tumor and cavernous sinus invasion in the evaluation of postoperative pituitary adenoma. Materials and Methods This single-institution retrospective study included 65 patients (mean age ± standard deviation, 54 years ± 10; 26 women) who underwent a combined imaging protocol including 3-mm MRI and 1-mm MRI+DLR for postoperative evaluation of pituitary adenoma between August and October 2019. Reference standards for correct diagnosis were established by using all available imaging resources, clinical histories, laboratory findings, surgical records, and pathology reports. The diagnostic performances of 3-mm MRI, 1-mm slice thickness MRI without DLR (hereafter, 1-mm MRI), and 1-mm MRI+DLR for identifying residual tumor and cavernous sinus invasion were evaluated by two readers and compared between the protocols. Results The performance of 1-mm MRI+DLR in the identification of residual tumor was comparable to that of 3-mm MRI (area under the receiver operating characteristic curve [AUC], 0.89-0.92 vs 0.85-0.89, respectively; P ≥ .09). In the identification of cavernous sinus invasion, the diagnostic performance of 1-mm MRI+DLR was higher than that of 3-mm MRI (AUC, 0.95-0.98 vs 0.83-0.87, respectively; P ≤ .02). Conventional 1-mm MRI (AUC, 0.82-0.83) showed comparable diagnostic performance to 3-mm MRI (AUC, 0.83-0.87) (P ≥ .38). With 1-mm MRI+DLR, residual tumor was diagnosed in 20 patients and cavernous sinus invasion was diagnosed in 14 patients, in whom these diagnoses were not made with 3-mm MRI. Conclusion In the postoperative evaluation of pituitary adenoma, 1-mm slice thickness MRI with deep learning-based reconstruction showed higher diagnostic performance than 3-mm slice thickness MRI in the identification of cavernous sinus invasion and comparable diagnostic performance to 3-mm slice thickness MRI in the identification of residual tumor. © RSNA, 2020 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kim M, Kim HS, Kim HJ, et al. Thin-Slice Pituitary MRI with Deep Learning-based Reconstruction: Diagnostic Performance in a Postoperative Setting. Radiology. 2020. PMID: 33141001. doi:10.1148/radiol.2020200723

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。