文献速递外周血管泌尿生殖儿科影像CTDSA

儿童肾动脉狭窄CT血管成像的诊断敏感度与特异度

Diagnostic sensitivity and specificity of CT angiography for renal artery stenosis in children.
PubMed 文献 · Pediatr Radiol · 2020-11-05

该回顾性研究以数字减影血管造影(DSA)为参考标准,评估儿童肾动脉狭窄(RAS)的CT血管成像诊断效能。23例患者共59条肾动脉中,CT血管成像诊断RAS的敏感度为90.0%、特异度为89.7%,并识别出全部主肾动脉狭窄病例。

要点

  • CT血管成像对儿童RAS诊断敏感度90.0%、特异度89.7%,以DSA为参考标准。
  • CT血管成像识别出全部主肾动脉狭窄病例。
  • 在转诊行DSA的患儿中,CT血管成像对儿童RAS诊断具有高敏感度和特异度。

核心结论

  • 在转诊行DSA的患者中,肾CT血管成像对儿童RAS诊断具有高敏感度和特异度。

研究设计与样本

  • 回顾性研究,纳入2012年1月至2019年5月因高血压评估RAS而行CT血管成像的0-18岁患者131例,其中23例有DSA对照。
  • 以DSA为参考标准,共分析59条肾动脉,比较CT血管成像与DSA的诊断结果。
  • 23例患者中男17例、女6例,平均年龄6岁3个月(范围3个月至14岁7个月)。

诊断标准与关键数值

  • CT血管成像诊断RAS的敏感度为90.0%、特异度为89.7%(以DSA为参考标准,59条肾动脉中CT血管成像真阳性18条、真阴性35条)。
  • 59条肾动脉中,CT血管成像判定异常22条,DSA判定异常20条。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Children with suspected renal artery stenosis (RAS) are screened with renal Doppler ultrasonography or computed tomography (CT) angiography/magnetic resonance (MR) angiography depending on institutional preference. CT angiography produces images with superior resolution, allowing higher quality multiplanar two-dimensional reformats and three-dimensional reconstructions. However, there is a paucity of data in the literature regarding the utility and diagnostic performance of renal CT angiography in pediatric RAS.

OBJECTIVE: The objective of this study is to retrospectively review our experience with renal CT angiography in the diagnosis of pediatric RAS relative to digital subtraction angiography (DSA) as the reference standard.

MATERIALS AND METHODS: All patients 0-18 years of age who underwent CT angiography for evaluation of RAS as a cause of hypertension between January 2012 and May 2019 were identified for the study. A total of 131 patients were identified, 23 of whom had DSA correlation.

RESULTS: Twenty-three patients (17 boys, 6 girls) with a mean age of 6 years 3 months (range: 3 months to 14 years 7 months) were included in this study. Of the 59 renal arteries studied by DSA, 22 were abnormal on CT angiography and 20 were abnormal on DSA. Of the 59 renal arteries, CT angiography was true positive in 18 and true negative in 35. The sensitivity and specificity of CT angiography for RAS diagnosis were 90.0% and 89.7%, respectively. CT angiography identified all cases of main RAS.

CONCLUSION: Renal CT angiography has a high sensitivity and specificity for pediatric RAS diagnosis in patients referred for DSA.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Orman G, Masand PM, Kukreja KU, et al. Diagnostic sensitivity and specificity of CT angiography for renal artery stenosis in children. Pediatr Radiol. 2020. PMID: 33151345. doi:10.1007/s00247-020-04852-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。