文献速递头颈儿科影像US

儿童梗阻性扁桃体肥大超声评估新方法

A Novel Assessment Method With Ultrasound for Obstructive Tonsillar Hypertrophy in Children.
PubMed 文献 · J Ultrasound Med · 2020-11-17

本研究纳入102例2-12岁儿童,以Brodsky分期为参考,用超声测量最窄扁桃体间距(ITD)与舌根最宽横径(TLTB)并计算比值。ITD/TLTB比值诊断梗阻性扁桃体肥大的AUC为0.991,最佳截断值≤0.3,敏感度96.5%、特异度95.6%。作者认为该法可客观判断气道梗阻程度,可能为扁桃体切除术决策提供参考。

要点

  • 超声测量ITD/TLTB比值可用于儿童梗阻性扁桃体肥大的客观评估。
  • ITD/TLTB比值≤0.3诊断梗阻性扁桃体肥大,敏感度96.5%、特异度95.6%。
  • 以Brodsky分期为参考,ITD/TLTB比值的AUC为0.991(95%CI 0.977-0.999)。

关键影像表现/征象

  • 按Brodsky分期,44.1%的患者为非梗阻性扁桃体肥大(I、II期),55.9%为梗阻性(III、IV期)。

诊断标准与关键数值

  • ITD/TLTB比值诊断梗阻性扁桃体肥大的AUC为0.991(95%CI 0.977-0.999)。
  • ITD/TLTB比值诊断梗阻性扁桃体肥大的最佳截断值为≤0.3,敏感度96.5%、特异度95.6%。

临床应用与阅片要点

  • 作者认为超声测量ITD/TLTB比值这一简便易行的方法可能为扁桃体切除术决策提供参考和指导。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a new method for the objective evaluation of airway obstruction due to tonsillar hypertrophy using ultrasound (US) in children.

METHODS: The oropharynx was examined in patients, and tonsil grades were evaluated according to the staging system of Brodsky et al (Int J Pediatr Otorhinolaryngol 1987; 13:149-156). The narrowest intertonsillar distance (ITD) and widest transverse length of the tongue base (TLTB) were then measured by US, and their ratio was calculated. The clinical value of US was investigated for the classification of tonsillar hypertrophies as nonobstructive or obstructive by matching the patients' clinical grades with the US data.

RESULTS: A total of 102 patients (age range, 2-12 years) were included in the study. According to the Brodsky staging system, 44.1% and 55.9% of the patients were in nonobstructive (stages I and II) and obstructive (stages III and IV) tonsillar hypertrophy groups, respectively. The area under the curve was 0.991 (95% confidence interval, 0.977-0.999) according to a receiver operating characteristic curve analysis between the Brodsky staging and the ITD/TLTB ratio. The optimal cutoff value for the ITD/TLTB ratio for the diagnosis of obstructive tonsillar hypertrophy was found to be 0.3 or less, which had 96.5% sensitivity and 95.6% specificity.

CONCLUSIONS: The degree of airway obstruction due to tonsillar hypertrophy can be objectively determined by US in children. An ITD/TLTB ratio of 0.3 or less was found to be compatible with obstructive tonsillar hypertrophy. This new and easily applicable evaluation method may provide considerable value and guidance for tonsillectomy decisions.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Sağtaş E, Mengi E, Kara CO, et al. A Novel Assessment Method With Ultrasound for Obstructive Tonsillar Hypertrophy in Children. J Ultrasound Med. 2020. PMID: 33200837. doi:10.1002/jum.15559

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。