文献速递外周血管介入CTDSA

双能CT血管成像在外周动脉闭塞性疾病中的应用:不同图像重建方法的诊断准确性

Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease: Diagnostic Accuracy of Different Image Reconstruction Approaches.
PubMed 文献 · Acad Radiol · 2020-11-12

回顾性纳入111例下肢双能CT血管成像患者,以数字减影血管造影为参考标准,比较五种重建方法对>50%狭窄的诊断准确性。各方法敏感度高(96.4%-98.6%)且无显著差异,但特异度(74.9%-92.2%)和准确性(86.9%-94.5%)差异显著,常规MPR整体诊断性能最高。

要点

  • 各重建方法对>50%下肢动脉狭窄的敏感度为96.4%-98.6%,无显著差异。
  • 特异度(74.9%-92.2%)和准确性(86.9%-94.5%)在不同重建方法间差异显著。
  • 常规MPR显示最高的整体诊断性能。

核心结论

  • 无论采用何种图像重建方法、血管钙化及管腔内对比剂衰减程度如何,下肢双能CT血管成像对显著狭窄均具有高敏感度。
  • 特异度和准确性在不同重建方法间存在差异,提示需使用MPR对潜在狭窄病变进行额外验证,以减少因CT血管成像假阳性导致的不必要有创数字减影血管造影。

研究设计与样本

  • IRB批准、符合HIPAA的回顾性研究,纳入111例(63例男性;平均年龄75.0±9.7岁)临床指征行下肢双能CT血管成像的患者。
  • 以数字减影血管造影为参考标准,视觉评估常规多平面重建(MPR)、曲面MPR(cMPR)、双能骨及钙化斑块减影(DE-CS)、最大密度投影(MIP)和DE-CS MPR五种重建方法对>50%狭窄的检测。
  • 在cMPR上实施自动客观狭窄分级,并评估血管钙化和管腔内对比剂对诊断性能的影响。

诊断标准与关键数值

  • 以数字减影血管造影为参考标准,视觉评估>50%下肢动脉狭窄。
  • 各重建方法检测狭窄的敏感度为96.4%-98.6%,特异度为74.9%-92.2%,准确性为86.9%-94.5%。

临床应用与阅片要点

  • 常规MPR整体诊断性能最高,可用于对潜在狭窄病变进行额外验证。
  • 严重血管壁钙化和管腔内对比剂衰减降低视觉评估的特异度,但不显著影响敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic accuracy of five DE-CTA image reconstruction approaches for detection of lower extremity arterial stenosis using digital subtraction angiography as reference standard.

METHODS: One hundred and eleven patients (63 males; mean age, 75.0 ± 9.7 years) who underwent clinically indicated lower extremity DE-CTA were included in this IRB-approved, HIPAA-compliant retrospective study. Routine multiplanar reconstructions (MPR), curved MPR (cMPR), DE-bone-and-calcified-plaque-subtraction (DE-CS), maximum-intensity projections (MIP), and DE-CS MPR were visually assessed for stenoses > 50%. Automatic objective stenosis grading was implemented on cMPRs. The effect of vessel calcification and luminal contrast on diagnostic performance was evaluated.

RESULTS: Sensitivity for stenosis detection was high (96.4%-98.6%) with no significant differences among reconstruction approaches. Specificity (74.9%-92.2%) and accuracy (86.9%-94.5%) varied significantly. Pronounced vessel wall calcification and inferior intraluminal contrast attenuation had no significant effect on sensitivity (calcification: p = 0.167 for MPR; 0.567 DE-CS MPR; 0.057 DE-CS MIP; 0.272 cMPR; 0.185 automatic grading; contrast attenuation: p = 1.000 for all reconstructions), but lead to reduced specificity in visual assessment (calcification: p = 0.002 for MPR; <0.001 DE-CS MPR, DE-CS MIP, and cMPR; contrast attenuation: p = 0.844 for MPR; 0.001 DE-CS MPR and DE-CS MIP; 0.420 cMPR). Routine MPR showed highest overall diagnostic performance.

CONCLUSION: Regardless of image reconstruction approach, vessel calcification and intraluminal contrast attenuation, lower extremity DE-CTA possesses high sensitivity for detection of significant stenoses. Specificity and accuracy vary between reconstruction approaches, indicating the need for additional verification of potential stenotic lesions by use of MPR to reduce the number of unnecessary invasive DSAs due to false-positive CTA findings.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Kosmala A, Weng AM, Schmid A, et al. Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease: Diagnostic Accuracy of Different Image Reconstruction Approaches. Acad Radiol. 2020. PMID: 33189548. doi:10.1016/j.acra.2020.10.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。