文献速递骨肌CTMR

不同相关对比物质值下双能CT虚拟去钙图像检测膝关节骨髓水肿的诊断准确性

Diagnostic accuracy of dual-energy CT virtual non-calcium images with different related contrast material values for the detection of bone marrow edema in knee.
PubMed 文献 · Eur J Radiol · 2020-11-02

这项前瞻性研究纳入23例患者(24个膝关节),以MRI为参考标准,评估双能CT虚拟去钙图像在不同相关对比物质值(1.25至1.75)下检测膝关节骨髓水肿的诊断准确性。结果显示相关对比物质值为1.45时曲线下面积最高(0.882),诊断准确性最高(达89.2%),骨髓水肿区与正常区CT值分别为-67.9 HU和-94.5 HU,差异有统计学意义(Z=-9.804,P<0.05)。

要点

  • 相关对比物质值1.45时虚拟去钙图像诊断膝关节骨髓水肿的曲线下面积最高(0.882)。
  • 相关对比物质值1.45时诊断准确性最高,达89.2%。
  • 骨髓水肿区CT值-67.9 HU与正常区-94.5 HU差异有统计学意义(Z=-9.804,P<0.05)。

核心结论

  • 相关对比物质值为1.45的虚拟去钙图像是检测膝关节骨髓水肿的最佳选择。

研究设计与样本

  • 前瞻性研究,纳入23例患者(24个膝关节),于2018年7月至2019年6月期间三周内完成双能CT和MRI检查,均有明确外伤史,每个膝关节分为12个区域,以MR图像为参考标准。

诊断标准与关键数值

  • 以MRI为参考标准,288个区域中MR显示骨髓水肿121个区域。
  • 相关对比物质值1.25、1.35、1.45、1.55、1.65、1.75的曲线下面积分别为0.633、0.674、0.882、0.684、0.651、0.649。
  • 相关对比物质值1.45时诊断准确性最高,达89.2%。
  • 相关对比物质值1.45时骨髓水肿区CT值为-67.9(1.7~-100.1)HU,正常区为-94.5(-69.7~-144.9)HU,差异有统计学意义(Z=-9.804,P<0.05)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The purpose of this study was to evaluate the diagnostic accuracy of different related contrast material (Rel.CM) values in dual-energy computed tomography (DECT) virtual non-calcium (VNCa) images for the detection of bone marrow edema (BME) in knee.

METHOD: This prospective study was approved by the institutional research ethics board, and written informed consent was obtained from all participants. Twenty-three patients (24 knees) who underwent dual-energy CT and MRI within three weeks from July 2018 to June 2019 with a definite history of trauma were enrolled. Each knee was divided into 12 regions. First, MR images served as the reference standard, Receiver operating characteristic (ROC) curve was used and diagnostic accuracy of VNCa images corresponding to different Rel.CM values (1.25, 1.35, 1.45, 1.55, 1.65, 1.75) were analyzed, aimed to select an optimal Rel.CM value of VNCa images for detecting BME. Then, CT values of the normal areas and BME areas were measured on the VNCa images corresponding to the optimal Rel.CM value for preliminary quantitative analysis. The rank-sum test was used to compare the differences of CT values between BME areas and normal bone marrow areas on the VNCa images.

RESULTS: The 24 knees were divided into 288 areas. MR Imaging showed BME in 121 areas. The areas under the ROC curve with different Rel.CM values (1.25, 1.35, 1.45, 1.55, 1.65, and 1.75) were 0.633, 0.674, 0.882, 0.684, 0.651, and 0.649, respectively. On the VNCa images of Rel.CM = 1.45, the diagnostic accuracy was the highest (up to 89.2 %), the CT values of the BME area and the normal area were -67.9 (1.7∼-100.1) HU and -94.5 (-69.7∼-144.9) HU, respectively, with statistical significance (Z=-9.804, P < 0.05).

CONCLUSIONS: The VNCa images with a Rel.CM value of 1.45 is optimal for the detection of BME in knee.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liang J, Fang Y, Jiang Y, et al. Diagnostic accuracy of dual-energy CT virtual non-calcium images with different related contrast material values for the detection of bone marrow edema in knee. Eur J Radiol. 2020. PMID: 33157370. doi:10.1016/j.ejrad.2020.109385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。