文献速递骨肌USMR

灰阶超声、能量多普勒超声和超声造影与增强MRI在显示膝骨关节炎滑膜炎中的诊断准确性比较

Diagnostic accuracy of grayscale, power Doppler and contrast-enhanced ultrasound compared with contrast-enhanced MRI in the visualization of synovitis in knee osteoarthritis.
PubMed 文献 · Eur J Radiol · 2020-11-02

该前瞻性研究纳入31例不同级别影像学膝骨关节炎患者,均行灰阶超声、能量多普勒超声、超声造影和增强MRI,以增强MRI为参考标准评估滑膜炎。灰阶超声和超声造影的滑膜炎评分与增强MRI显著相关;灰阶超声总体准确性有限,联合能量多普勒或超声造影可提高轻度滑膜炎的诊断性能,但对中度滑膜炎无额外价值。

要点

  • 灰阶超声诊断轻度滑膜炎的AUC为0.781,联合能量多普勒或超声造影后AUC分别升至0.862和0.885。
  • 能量多普勒超声诊断轻度滑膜炎敏感度0.905、特异度0.500,灰阶超声敏感度0.667、特异度0.700。
  • 中度滑膜炎灰阶超声AUC为0.882,能量多普勒和超声造影未显示额外价值。

关键影像表现/征象

  • 灰阶超声滑膜炎评分与增强MRI显著相关(ρ=0.608,p<0.001)。
  • 超声造影滑膜炎评分与增强MRI显著相关(ρ=0.391,p=0.033)。

诊断标准与关键数值

  • 轻度滑膜炎:灰阶超声AUC 0.781(95%CI 0.609-0.953),敏感度0.667(0.431-0.845),特异度0.700(0.354-0.919)。
  • 轻度滑膜炎:能量多普勒超声AUC 0.788(0.622-0.954),敏感度0.905(0.682-0.983),特异度0.500(0.201-0.799)。
  • 轻度滑膜炎:超声造影AUC 0.653(0.452-0.853),敏感度0.550(0.320-0.762),特异度0.700(0.354-0.919)。
  • 轻度滑膜炎:灰阶超声联合能量多普勒AUC 0.862(0.735-0.989),联合超声造影AUC 0.823(0.666-0.979),联合两者AUC 0.885(0.767-1.000)。
  • 中度滑膜炎:灰阶超声AUC 0.882(0.750-1.000),能量多普勒和超声造影未观察到额外价值。

临床应用与阅片要点

  • 以增强MRI为参考标准时,灰阶超声对轻度滑膜炎的敏感度有限,联合能量多普勒或超声造影可提高诊断性能。
  • 对于中度滑膜炎,灰阶超声AUC已达0.882,联合能量多普勒或超声造影未显示额外价值。
  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic accuracy of grayscale (GSUS), power Doppler (PDUS) and contrast-enhanced ultrasound (CEUS) for detecting synovitis in knee osteoarthritis (OA).

METHOD: Patients with different degrees of radiographic knee OA were included prospectively. All underwent GSUS, PDUS, CEUS, and contrast-enhanced magnetic resonance imaging (CE-MRI), on which synovitis was assessed semi-quantitatively. Correlations of synovitis severity on ultrasound based techniques with CE-MRI were determined. Receiver operating characteristic (ROC) analysis was performed to assess diagnostic performance of GSUS, PDUS, and CEUS, for detecting synovitis, using CE-MRI as reference-standard.

RESULTS: In the 31 patients included, synovitis scoring on GSUS and CEUS was significantly correlated (ρ = 0.608, p < 0.001 and ρ = 0.391, p = 0.033) with CE-MRI. For detecting mild synovitis, the area under the curve (AUC) was 0.781 (95 %CI 0.609-0.953) for GSUS, 0.788 (0.622-0.954) for PDUS, and 0.653 (0.452-0.853) for CEUS. Sensitivity and specificity were 0.667 (0.431-0.845) and 0.700 (0.354-0.919) for GSUS, 0.905 (0.682-0.983) and 0.500 (0.201-0.799) for PDUS, and 0.550 (0.320-0.762) and 0.700 (0.354-0.919) for CEUS, respectively. The AUC of GSUS increased to 0.862 (0.735-0.989), 0.823 (0.666-0.979), and 0.885 (0.767-1.000), when combined with PDUS, CEUS, or both, respectively. For detecting moderate synovitis, the AUC of GSUS was higher (0.882 (0.750-1.000)) and no added value of PDUS and CEUS was observed.

CONCLUSIONS: GSUS has limited overall accuracy for detecting synovitis in knee OA. When GSUS is combined with PDUS or CEUS, overall diagnostic performance improves for detecting mild synovitis, but not for moderate synovitis.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. de Vries BA, Breda SJ, Meuffels DE, et al. Diagnostic accuracy of grayscale, power Doppler and contrast-enhanced ultrasound compared with contrast-enhanced MRI in the visualization of synovitis in knee osteoarthritis. Eur J Radiol. 2020. PMID: 33157371. doi:10.1016/j.ejrad.2020.109392

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。