磁共振成像与超声评估II区屈肌腱部分撕裂的比较:一项尸体研究
研究在8具新鲜冷冻上肢尸体标本的32个手指上,将指深屈肌腱随机分为完整、低级别撕裂和高级别撕裂三组,由同一名盲法肌肉骨骼放射科医生先后进行动态超声和手线圈磁共振成像评估。超声诊断高级别撕裂的敏感度和特异度分别为0.5和1.0,磁共振成像分别为0.2和1.0。作者认为两者均能判断高级别撕裂,磁共振成像特异度更高,超声虽是较低特异度的替代方案但合理且更便宜。
要点
- 超声诊断高级别部分屈肌腱撕裂敏感度0.5、特异度1.0,磁共振成像敏感度0.2、特异度1.0。
- 磁共振成像在识别高级别部分屈肌腱撕裂方面比超声更特异。
- 超声特异度较低,但作为评估有临床意义的高级部分屈肌腱撕裂的替代方案合理且更便宜。
核心结论
- 超声和磁共振成像均足以判断高级别屈肌腱撕裂的存在。
- 磁共振成像在识别高级别部分屈肌腱撕裂方面比超声更特异。
- 超声特异度较低,但在评估有临床意义的高级部分屈肌腱撕裂时,是合理且较磁共振成像便宜的替代方案。
研究设计与样本
- 尸体研究,对8具新鲜冷冻上肢尸体标本的32个手指进行解剖。
- 将指深屈肌腱随机分为完整、低级别撕裂和高级别撕裂3组。
- 由一名盲法肌肉骨骼放射科医生进行动态超声检查,同一批标本随后接受手线圈磁共振成像,由同一名盲法放射科医生阅片。
- 计算磁共振成像的诊断性能指标,并与超声评估的相应指标进行比较。
诊断标准与关键数值
- 超声评估高级别撕裂:敏感度0.5,特异度1.0,阳性似然比∞,阴性似然比0.50。
- 磁共振成像评估高级别撕裂:敏感度0.2,特异度1.0,阳性似然比∞,阴性似然比0.80。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Surgical intervention for zone II high-grade partial flexor tendon lacerations is often required when more than half of the tendon width is torn. Reliable noninvasive tests are critical for optimizing clinical decision making. Our team previously investigated the use of ultrasound (US) for identification of high-grade zone II flexor digitorum profundus lacerations. In this study, we compared magnetic resonance imaging (MRI) to US for the evaluation of high-grade partial flexor tendon lacerations in cadaveric specimens.
METHODS: Dissection of 32 digits in 8 fresh-frozen upper extremity cadaveric specimens was performed. The flexor digitorum profundus tendons were randomized into 3 groups: intact, low-grade laceration, and high-grade laceration. A dynamic US examination was performed by a blinded musculoskeletal radiologist. The same specimens underwent hand coil MRI, which was read by the same blinded radiologist. Magnetic resonance imaging test performance metrics were calculated and compared to those computed for the US evaluation.
RESULTS: For US evaluation of high-grade lacerations, the sensitivity and specificity were 0.5 and 1.0, with positive likelihood ratio (LR+) and negative likelihood ratio (LR-) values of ∞ and 0.50, respectively. The sensitivity and specificity for MRI evaluation were 0.2 and 1.0, with LR+ and LR- values of ∞ and 0.80.
CONCLUSIONS: Both US and MRI are adequate at determining the presence of a high-grade laceration. Magnetic resonance imaging was more specific than US in identification of high-grade partial flexor tendon lacerations. Although less specific, US is a reasonable and less-expensive alternative to MRI when evaluating for clinically significant high-grade partial flexor tendon lacerations.
引用
- Stephens AR, Buterbaugh KL, Gordon JA, et al. Comparison of Magnetic Resonance Imaging and Ultrasound Evaluations of Zone II Partial Flexor Tendon Lacerations: A Cadaveric Study. J Ultrasound Med. 2020. PMID: 33174636. doi:10.1002/jum.15553
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。