文献速递骨肌MR

骨骼肿瘤范围评估:各向同性T1加权3D序列是否足够?

Determination of skeletal tumor extent: is an isotropic T1-weighted 3D sequence adequate?
PubMed 文献 · Eur Radiol · 2020-11-12

研究纳入34例患者,在3-T MRI上比较3D CAIPIRINHA SPACE T1序列与常规2D T1 TSE序列评估骨肿瘤范围与特征的表现。两种序列在肿瘤长度、肿瘤至关节距离、信号强度、边缘及骨外延伸评估上无差异,SNR与CNR亦无差异,3DT1采集时间更短且无需多平面2DT1采集。

要点

  • 3DT1与2DT1在骨肿瘤长度及肿瘤至关节距离测量上无差异(p=0.95)。
  • 3DT1与2DT1评估肿瘤信号强度、边缘及骨外延伸的结果相似。
  • 3DT1平均采集时间235 s,短于两个平面2DT1联合的381 s。

核心结论

  • 加速3D CAIPIRINHA SPACE T1序列对髓内骨肿瘤范围的评估与常规2DT1 MRI相当,肿瘤特征评估相似。
  • 各向同性容积采集与多平面重建能力可使骨肿瘤评估无需多平面2DT1采集。

研究设计与样本

  • 研究纳入34例接受3-T MRI检查的患者,均行3DT1(CAIPIRINHA SPACE TSE)与2DT1(TSE)序列。
  • 两名放射科医师独立评估肿瘤位置、大小/长度、肿瘤至关节距离、信号强度、边缘/骨外延伸及SNR与CNR。

关键影像表现/征象

  • 肿瘤位于长骨20/36(55.5%)、骨盆骨16/36(44.4%)。
  • 3DT1与2DT1上肿瘤分别呈低信号17/36(47.2%)vs 17/36(47.2%)、等信号12/36(33.3%)vs 12/36(33.3%)、高信号7/36(19.4%)vs 7/36(19.4%)。
  • 3DT1与2DT1评估肿瘤边缘及骨外延伸相似。

诊断标准与关键数值

  • 3DT1与2DT1测量肿瘤长度及肿瘤至关节距离无差异(p=0.95)。
  • 3DT1与2DT1之间肿瘤SNR或CNR无差异(p>0.05)。
  • 3DT1平均采集时间235 s(±42 s,范围156-372),两个平面2DT1序列联合(冠状面与轴面)平均采集时间381 s(±73 s,范围312-523)。

临床应用与阅片要点

  • 3DT1的各向同性容积采集与多平面重建能力可使骨肿瘤评估无需多平面2DT1采集。
  • 3DT1在评估骨肿瘤特征方面与2DT1表现相当,且采集更快、分辨率更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To test the hypothesis that an accelerated, T1-weighted 3D CAIPIRINHA SPACE sequence with isotropic voxel size offers a similar performance to conventional T1-weighted 2D TSE (turbo spin echo) for the evaluation of bone tumor extent and characteristics.

METHODS: Thirty-four patients who underwent 3-T MRI with 3DT1 (CAIPIRINHA SPACE TSE) and 2DT1 (TSE) were included. Sequence acquisition time was reported. Two radiologists independently evaluated each technique for tumor location, size/length, tumor-to-joint distance, signal intensity, margin/extraosseous extension, and signal-to-noise (SNR) and contrast-to-noise (CNR) ratios.

RESULTS: Tumors were located in long (20/36, 55.5%) and pelvic (16/36, 44.4%) bones. 3DT1 sequence required an average acquisition time of 235 s (± 42 s, range 156-372), while two plane 2DT1 sequences combined (coronal and axial) had an average acquisition time of 381 s (± 73 s, range 312-523). There was no difference in the measurements of tumor length and tumor-to-joint distance (p = 0.95) between 3DT1 and 2DT1 images. Tumors were hypointense (17/36, 47.2% vs 17/36, 47.2%), isointense (12/36, 33.3% vs 12/36, 33.3%), or hyperintense (7/36, 19.4% vs 7/36, 19.4%) on 3DT1 vs 2DT1, respectively. Assessment of tumor margins and extraosseous extension was similar, and there was no difference in tumor SNR or CNR (p > 0.05).

CONCLUSIONS: An accelerated 3D CAIPIRINHA SPACE T1 sequence provides comparable assessments of intramedullary bone tumor extent and similar tumor characteristics to conventional 2DT1 MRI. For the assessment of bone tumors, the isotropic volume acquisition and multiplanar reformation capability of the 3DT1 datasets can obviate the need for 2DT1 acquisitions in multiple planes.

KEY POINTS: • 3DT1 offers an equivalent performance to 2DT1 for the assessment of bone tumor characteristics, with faster and higher resolution capability, obviating the need for acquiring 2DT1 in multiple planes. • There was no difference in the measurements of tumor length and tumor-to-joint distance obtained on 3DT1 and 2DT1 images. • There was no difference in signal-to-noise ratio (SNR) or contrast-to-noise ratio (CNR) measures between 3DT1 and 2DT1.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Luna R, Fritz J, Del Grande F, et al. Determination of skeletal tumor extent: is an isotropic T1-weighted 3D sequence adequate? Eur Radiol. 2020. PMID: 33179165. doi:10.1007/s00330-020-07394-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。