非增强超声不是测量良性甲状腺结节射频消融后坏死消融体积的满意方法:与超声造影的比较

Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound.
PubMed 文献 · Eur Radiol · 2020-10-31

本研究纳入173例患者共190个良性甲状腺结节,在射频消融后随访中用常规超声(灰阶和多普勒)与超声造影(CEUS)测量消融体积。结果显示常规超声测得的消融体积显著大于CEUS,且两种方法在测量消融体积时的观察者内和观察者间信度及一致性均不理想;当需要进一步评估消融体积或怀疑结节再生长时,应考虑使用CEUS。

要点

  • 常规超声测得的消融体积显著大于CEUS测值(p < 0.001)。
  • 常规超声测量消融体积的观察者内和观察者间信度及与CEUS的一致性均不理想。
  • 当需要评估消融体积或怀疑结节再生长时,应考虑使用CEUS。

诊断标准与关键数值

  • 常规超声测得的消融体积显著大于CEUS测值(p < 0.001)。
  • 观察者内和观察者间信度随随访时间延长而下降,至12个月时两个亚组均为中等信度(所有ICC < 0.75)。
  • 平均差和LOA随随访时间延长而增大和变宽。
  • 一致性最佳见于1个月时< 10 ml的结节,平均差为1.166,LOA为0.413至3.294。

临床应用与阅片要点

  • 常规超声测量消融体积的观察者内和观察者间信度及与CEUS的一致性均不理想。
  • 当需要进一步评估消融体积或怀疑结节再生长时,应考虑使用CEUS。
  • 在测量消融体积时,CEUS应优先于常规超声(灰阶和多普勒)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the intra- and inter-observer reliability and agreement between gray-scale and Doppler ultrasound (US) and contrast-enhanced ultrasound (CEUS) in measuring ablated volume (Va) after radiofrequency ablation (RFA) for benign thyroid nodules.

METHODS: A total of 173 patients with 190 benign thyroid nodules who underwent RFA were included in this study. After RFA, the total volume of ablated nodule was divided into Va and the incompletely treated vital volume. Patients were followed up at 1, 3, 6, 12 months, and every 12 months thereafter. Two independent observers measured Va using US and CEUS during the same follow-up visit. The intra- and inter-observer reliability of the two measurement modalities was assessed using intraclass correlation coefficient (ICC) with 95% confidence interval. The Bland-Altman analysis was used to evaluate agreement, which was expressed as a mean difference with 95% limits of agreement (LOA).

RESULTS: The mean follow-up time was 23.17 ± 12.70 months. Va measured by US was significantly larger than by CEUS (p < 0.001). The intra- and inter-observer reliability decreased over the follow-up period and became moderate in both subgroups at 12 months (all ICC < 0.75). The mean difference and LOA became larger and wider during the follow-up. The best agreement was found in nodules < 10 ml at 1 month with a mean difference of 1.166 and LOA between 0.413 and 3.294.

CONCLUSIONS: The intra- and inter-observer reliability and agreement of US and CEUS in measuring Va were unsatisfactory. CEUS should be considered when Va was needed for further evaluation or in the case of nodules with suspected regrowth.

KEY POINTS: • Va measured by gray-scale and Doppler US was significantly larger than that by CEUS. • Va measured by gray-scale and Doppler US lacked intra- and inter-observer reliability and agreement with CEUS. • CEUS should be preceded to gray-scale and Doppler US for the measurement of Va.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yan L, Luo Y, Xiao J, et al. Non-enhanced ultrasound is not a satisfactory modality for measuring necrotic ablated volume after radiofrequency ablation of benign thyroid nodules: a comparison with contrast-enhanced ultrasound. Eur Radiol. 2020. PMID: 33128600. doi:10.1007/s00330-020-07398-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。