源自简化乳腺MRI的最大强度投影图像:在乳腺癌保留乳头乳房切除术中有望减少不必要的乳头下活检
该前瞻性研究纳入2016年4月至2019年5月临床乳头乳晕复合体正常的乳腺癌患者843例,评估简化乳腺MRI生成的最大强度投影(MIP)图像排除隐匿性乳头乳晕复合体(NAC)受累的价值。结果显示,不对称乳头强化(OR 6.098,p<0.001)和肿瘤-乳头距离(OR 0.564,p=0.003)是独立预测因子;「不对称乳头强化或肿瘤-乳头距离≤15 mm」并联模型AUC最高(0.838),MIP图像排除隐匿性NAC受累的阴性预测值为99.5%。结论认为单张MIP图像有助于排除隐匿性NAC受累,减少保留乳头乳房切除术中不必要的乳头下活检。
要点
- MIP图像上不对称乳头强化和肿瘤-乳头距离是隐匿性NAC受累的独立预测因子。
- 「不对称乳头强化或肿瘤-乳头距离≤15 mm」并联模型AUC最高,为0.838。
- MIP图像排除隐匿性NAC受累的阴性预测值达99.5%,适用于各患者亚组。
关键影像表现/征象
- 在MIP图像上评估不对称乳头强化、肿瘤-乳头距离、肿瘤直径、病变类型、位置和多灶性。
- MIP图像上不对称乳头强化(OR 6.098,p<0.001)和肿瘤-乳头距离(OR 0.564,p=0.003)为隐匿性NAC受累的独立预测因子。
诊断标准与关键数值
- 「不对称乳头强化或肿瘤-乳头距离≤15 mm」并联检验模型在预测模型中AUC最高,为0.838。
- MIP图像排除隐匿性NAC受累的阴性预测值为99.5%,该结果适用于各患者亚组。
临床应用与阅片要点
- MIP图像上阴性发现有助于筛选隐匿性NAC受累风险极低的患者,此类患者可省略保留乳头乳房切除术中不必要的术中乳头下活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the value of a maximum-intensity projection (MIP) image derived from abbreviated breast MRI for excluding occult nipple-areolar complex (NAC) involvement in patients with breast cancer.
METHODS: This prospective study included breast cancer patients with clinically normal NACs between April 2016 and May 2019. Abbreviated breast MRI was performed, and an MIP image was generated for each patient. MIP images were examined for the following features: asymmetric nipple enhancement, tumor-nipple distance (TND), tumor diameter, lesion type, location, and multifocality. Independent predictive MIP features for occult NAC involvement were identified by univariable and multivariable logistic regression analyses. Models based on independent predictive MIP features were developed, and their diagnostic performances were evaluated using ROC analysis. The utility of an MIP image for excluding occult NAC involvement was assessed by considering NPVs across patient subgroups.
RESULTS: Eight hundred forty-three patients (67 NAC-positive and 776 NAC-negative) were enrolled. On MIP images, asymmetric nipple enhancement (odds ratio, 6.098; p < 0.001) and TND (odds ratio, 0.564; p = 0.003) were independent predictors of occult NAC involvement. A parallel test model of "asymmetric nipple enhancement or TND ≤ 15 mm" yielded the highest AUC value (0.838) among prediction models. The NPV of MIP images for excluding occult NAC involvement was 99.5%, which was applicable across various patient subgroups.
CONCLUSIONS: A single MIP image derived from abbreviated breast MRI has utility for excluding occult NAC involvement in breast cancer patients and reducing the number of unnecessary sub-nipple biopsies in nipple-sparing mastectomy.
KEY POINTS: • On MIP images derived from abbreviated breast MRI, asymmetric nipple enhancement and tumor-nipple distance were independent predictors for occult nipple involvement in patients with breast cancer. • Negative findings on MIP image can help select patients at minimal risk of occult nipple involvement, for whom unnecessary intraoperative sub-nipple biopsies in nipple-sparing mastectomy can be omitted.
引用
- Liu Z, Li X, Feng B, et al. MIP image derived from abbreviated breast MRI: potential to reduce unnecessary sub-nipple biopsies during nipple-sparing mastectomy for breast cancer. Eur Radiol. 2020. PMID: 33247343. doi:10.1007/s00330-020-07550-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。