优化乳腺癌前哨淋巴结状态影像组学分析中的瘤周区域尺寸
本研究回顾性纳入162例乳腺癌患者的动态增强MRI,评估瘤周特征对前哨淋巴结转移预测的增益,并比较2、4、6、8 mm四种瘤周厚度。验证集中两位放射科医师勾画的ROI在加入瘤周特征后准确率均从0.704提升至0.796,提升幅度受瘤周尺寸选择影响。
要点
- 瘤周特征可提升乳腺癌前哨淋巴结状态影像组学预测的准确率。
- 验证集中加入瘤周特征后准确率由0.704升至0.796。
- 瘤周尺寸选择影响预测性能提升幅度,需在研究中优化。
核心结论
- 系统探讨了瘤周区域尺寸对影像组学预测性能提升的影响,瘤周尺寸的选择取决于ROI勾画并会影响模型最终预测性能,提示未来影像组学研究应优化瘤周特征。
研究设计与样本
- 回顾性研究,纳入162例乳腺癌患者的动态增强MRI扫描。
- 由两位专家放射科医师手动勾画肿瘤ROI,并通过膨胀生成厚度为2 mm、4 mm、6 mm和8 mm的瘤周区域。
- 在训练集(约67%病例)中建立含与不含不同瘤周厚度特征的预测模型,在独立验证集(其余约33%)中测试性能。
诊断标准与关键数值
- 验证集中使用两位放射科医师的ROI时,加入瘤周特征后准确率均从0.704提升至0.796。
临床应用与阅片要点
- 作者认为瘤周特征应在其后的影像组学研究中加以优化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Peritumoral features have been suggested to be useful in improving the prediction performance of radiomic models. The aim of this study is to systematically investigate the prediction performance improvement for sentinel lymph node (SLN) status in breast cancer from peritumoral features in radiomic analysis by exploring the effect of peritumoral region sizes.
MATERIALS AND METHODS: This retrospective study was performed using dynamic contrast-enhanced MRI scans of 162 breast cancer patients. The effect of peritumoral features was evaluated in a radiomics pipeline for predicting SLN metastasis in breast cancer. Peritumoral regions were generated by dilating the tumor regions-of-interest (ROIs) manually annotated by two expert radiologists, with thicknesses of 2 mm, 4 mm, 6 mm, and 8 mm. The prediction models were established in the training set (∼67% of cases) using the radiomics pipeline with and without peritumoral features derived from different peritumoral thicknesses. The prediction performance was tested in an independent validation set (the remaining ∼33%).
RESULTS: For this specific application, the accuracy in the validation set when using the two radiologists' ROIs could be both improved from 0.704 to 0.796 by incorporating peritumoral features. The choice of the peritumoral size could affect the level of improvement.
CONCLUSION: This study systematically investigates the effect of peritumoral region sizes in radiomic analysis for prediction performance improvement. The choice of the peritumoral size is dependent on the ROI drawing and would affect the final prediction performance of radiomic models, suggesting that peritumoral features should be optimized in future radiomics studies.
引用
- Ding J, Chen S, Serrano Sosa M, et al. Optimizing the Peritumoral Region Size in Radiomics Analysis for Sentinel Lymph Node Status Prediction in Breast Cancer. Acad Radiol. 2020. PMID: 33160860. doi:10.1016/j.acra.2020.10.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。