实时剪切波弹性成像在诊断子宫内膜癌肌层浸润深度中的应用价值
本研究纳入71例I期子宫内膜癌肌层浸润患者和37例正常体检者,分为浅肌层浸润组、深肌层浸润组和正常对照组,采用实时剪切波弹性成像测量Emax、Emean和Esd。结果显示以Emax≥32.22 kPa或Emean≥27.54 kPa作为诊断肌层浸润的超声标准的使用率为92.9%,诊断肌层浸润的准确率Emax截断值为96.1%、Emean截断值为94.1%、Esd截断值为86.3%。结论认为实时剪切波弹性成像有助于判断子宫内膜癌肌层浸润深度。
要点
- 以Emax≥32.22 kPa或Emean≥27.54 kPa作为诊断肌层浸润的超声标准的使用率为92.9%。
- 诊断肌层浸润的准确率:Emax截断值96.1%,Emean截断值94.1%,Esd截断值86.3%。
- 正常对照组浅肌层与深肌层弹性模量值无差异(P > 0.05)。
核心结论
- 实时剪切波弹性成像有助于判断子宫内膜癌肌层浸润深度。
研究设计与样本
- 纳入71例I期子宫内膜癌肌层浸润患者和37例正常体检者,分为子宫内膜癌浅肌层浸润组、深肌层浸润组和正常对照组。
- 完成二维超声检查后切换至实时剪切波弹性成像模式测量弹性值Emax、Emean和Esd。
关键影像表现/征象
- 正常对照组近内膜面浅肌层与近浆膜面深肌层的弹性模量值比较无差异(P > 0.05)。
- 子宫内膜癌浅肌层浸润组浸润肌层与未浸润肌层的Emax和Emean有显著差异,Esd无差异(P > 0.05)。
- 正常对照组与深肌层浸润组之间弹性模量有显著差异(P < 0.05),Emean和Emax无差异,Esd有差异。
诊断标准与关键数值
- 诊断肌层浸润的准确率:Emax截断值78.9%,Emean截断值82.5%。
- 以Emax≥32.22 kPa或Emean≥27.54 kPa作为诊断肌层浸润的超声标准的使用率为92.9%。
- 诊断肌层浸润的准确率:Emax截断值96.1%,Emean截断值94.1%,Esd截断值86.3%。
临床应用与阅片要点
- 实时剪切波弹性成像测量Emax、Emean和Esd可用于辅助判断子宫内膜癌肌层浸润深度。
- 以Emax≥32.22 kPa或Emean≥27.54 kPa作为诊断肌层浸润的超声标准的使用率为92.9%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the clinical value of real-time shear wave ultrasonic elastography in diagnosing the depth of infiltrating muscularis of endometrial cancer.
METHODS: Seventy-one patients with stage I endometrial cancer infiltrating the myometrium and 37 patients with normal physical examination were enrolled and divided into three groups: endometrial cancer superficial muscle infiltration group, endometrial cancer deep muscle infiltration group, and normal control group. After completing 2-dimensional ultrasound examination, each patient switched to the real-time shear wave elastography mode to measure the elasticity values Emax, Emean, and Esd.
RESULTS: For control group, comparison of elastic modulus values between superficial muscular layer near the intimal surface and the deep muscular layer near the serosa surface showed no difference (P > 0.05). For endometrial cancer superficial muscular infiltration group, significant difference was found regarding the elastic modulus values of infiltrated muscular layer and uninfiltrated muscular layer (Emax and Emean) without difference for Esd (P > 0.05). A significant difference of elastic modulus was observed between control group and deep myometrial infiltration group (P < 0.05) without difference of Emean or Emax but with difference of Esd. The accuracy in diagnosing muscular layer infiltration was 78.9% for Emax cutoff and 82.5% for Emean cutoff. The rate of using Emax ≥32.22 kPa or Emean ≥27.54 kPa as the ultrasound standard for diagnosing myometrium infiltration was 92.9%. The accuracy for the diagnosis of muscular layer infiltration was 96.1% for Emax cutoff, 94.1% for Emean cutoff and 86.3% for Esd cutoff.
CONCLUSION: Real-time shear wave elastography is helpful to determine the depth of infiltrating myometrium of endometrial cancer.
引用
- Zhao HX, Du YY, Guo YJ, et al. Application Value of Real-Time Shear Wave Elastography in Diagnosing the Depth of Infiltrating Muscular Layer of Endometrial Cancer. J Ultrasound Med. 2020. PMID: 33216384. doi:10.1002/jum.15568
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。