经会阴超声评估脐带脱垂处理手法对胎头上抬的效果
前瞻性观察研究纳入20例足月择期剖宫产孕妇,用经会阴超声测量旁矢状面进展角等指标,比较不同手法上抬胎头的效果。膝胸位效果最强(旁矢状面进展角从基线103.6°降至80.7°,P<0.001),其次为膀胱灌注500 mL和300 mL生理盐水;灌注100 mL、Trendelenburg位和抬高臀部效果有限。
要点
- 膝胸位使旁矢状面进展角由基线103.6°降至80.7°,上抬胎头效果最强。
- 膀胱灌注500 mL和300 mL生理盐水后旁矢状面进展角分别降至89.9°和94.4°,效果次之。
- 灌注100 mL、Trendelenburg位和抬高臀部对上抬胎头效果有限。
诊断标准与关键数值
- 基线中位旁矢状面进展角为103.6°。
- 膝胸位旁矢状面进展角为80.7°(P<0.001),较基线降低。
- 膀胱灌注500 mL生理盐水后旁矢状面进展角为89.9°(P<0.001),较基线降低。
- 膀胱灌注300 mL生理盐水后旁矢状面进展角为94.4°(P<0.001),较基线降低。
- 膀胱灌注100 mL生理盐水后旁矢状面进展角为96.1°(P=0.001)、Trendelenburg位为96.8°(P=0.014)、抬高臀部为98.3°(P=0.033),均较基线降低。
临床应用与阅片要点
- 经会阴超声可用于客观评估不同手法对胎头的上抬程度。
- 膝胸位、Trendelenburg位和抬高臀部的胎头上抬效果与初始胎头位置无关。
- 膀胱灌注的上抬效果在初始胎头位置较低时更大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess objectively the degree of fetal head elevation achieved by different maneuvers commonly used for managing umbilical cord prolapse.
METHODS: This was a prospective observational study of pregnant women at term before elective Cesarean delivery. A baseline assessment of fetal head station was performed with the woman in the supine position, using transperineal ultrasound for measuring the parasagittal angle of progression (psAOP), head-symphysis distance (HSD) and head-perineum distance (HPD). The ultrasonographic measurements of fetal head station were repeated during different maneuvers, including elevation of the maternal buttocks using a wedge, knee-chest position, Trendelenburg position with a 15° tilt and filling the maternal urinary bladder with 100 mL, 300 mL and 500 mL of normal saline. The measurements obtained during the maneuvers were compared with the baseline measurements.
RESULTS: Twenty pregnant women scheduled for elective Cesarean section at term were included in the study. When compared with baseline (median psAOP, 103.6°), the knee-chest position gave the strongest elevation effect, with the greatest reduction in psAOP (psAOP, 80.7°; P < 0.001), followed by filling the bladder with 500 mL (psAOP, 89.9°; P < 0.001) and 300 mL (psAOP, 94.4°; P < 0.001) of normal saline. Filling the maternal bladder with 100 mL of normal saline (psAOP, 96.1°; P = 0.001), the Trendelenburg position (psAOP, 96.8°; P = 0.014) and elevating the maternal buttocks (psAOP, 98.3°; P = 0.033) gave modest elevation effects. Similar findings were reported for HSD and HPD. The fetal head elevation effects of the knee-chest position, Trendelenburg position and elevation of the maternal buttocks were independent of the initial fetal head station, but that of bladder filling was greater when the initial head station was low.
CONCLUSIONS: To elevate the fetal presenting part, the knee-chest position provides the best effect, followed by filling the maternal urinary bladder with 500 mL then 300 mL of fluid, respectively. Filling the bladder with 100 mL of fluid, the Trendelenburg position and elevation of the maternal buttocks have modest effects. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Kwan AHW, Chaemsaithong P, Wong L, et al. Transperineal ultrasound assessment of fetal head elevation by maneuvers used for managing umbilical cord prolapse. Ultrasound Obstet Gynecol. 2021. PMID: 33219729. doi:10.1002/uog.23544
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。