文献速递腹部CT

多期双能CT碘图无创评估肝硬化:与终末期肝病模型评分的相关性

Non-invasive assessment of cirrhosis using multiphasic dual-energy CT iodine maps: correlation with model for end-stage liver disease score.
PubMed 文献 · Abdom Radiol (NY) · 2020-11-19

本研究回顾性纳入40例肝硬化和28例非肝硬化患者,行多期双能CT肝脏协议扫描,计算肝、主动脉、肝动脉和门静脉的碘值及碘斜率λ。结果显示碘斜率在两组间有显著差异,与MELD评分呈正相关,鉴别肝硬化的AUROC为0.71-0.75,提示多期DECT碘定量可能作为无创评估肝硬化和疾病严重程度的方法。

要点

  • 多期DECT碘斜率在肝硬化与非肝硬化患者间有显著差异。
  • 碘斜率与MELD评分呈正相关,可能反映疾病严重程度。
  • 鉴别肝硬化的AUROC为0.71-0.75,诊断准确性可接受。

关键影像表现/征象

  • 碘斜率λ平衡-动脉期在尾状叶、左叶、右叶和门静脉均显著高于非肝硬化组。
  • 碘斜率λ平衡-门静脉期在右叶和左叶显著高于非肝硬化组。

诊断标准与关键数值

  • λ平衡-动脉期鉴别肝硬化的AUROC:左叶0.72(P=0.002),右叶0.71(P=0.003),门静脉0.75(P=0.001)。
  • λ平衡-门静脉期右叶鉴别肝硬化的AUROC为0.73(P=0.001)。
  • MELD评分与λ平衡-动脉期尾状叶(ρ=0.34,P=0.004)、λ平衡-门静脉期尾状叶(ρ=0.26,P=0.028)和右叶(ρ=0.33,P=0.007)呈正相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine whether multiphasic dual-energy (DE) CT iodine quantitation correlates with the severity of chronic liver disease.

METHODS: We retrospectively included 40 cirrhotic and 28 non-cirrhotic patients who underwent a multiphasic liver protocol DECT. All three phases (arterial, portal venous (PVP), and equilibrium) were performed in DE mode. Iodine (I) values (mg I/ml) were obtained by placing regions of interest in the liver, aorta, common hepatic artery, and portal vein (PV). Iodine slopes (λ) were calculated as follows: (Iequilibrium-Iarterial)/time and (Iequilibrium-IPVP)/time. Spearman correlations between λ and MELD scores were evaluated, and the area under the curve of the receiver operating characteristic (AUROC) was calculated to distinguish cirrhotic and non-cirrhotic patients.

RESULTS: Cirrhotic and non-cirrhotic patients had significantly different λequilibrium-arterial [IQR] for the caudate (λ = 2.08 [1.39-2.98] vs 1.46 [0.76-1.93], P = 0.007), left (λ = 2.05 [1.50-2.76] vs 1.51 [0.59-1.90], P = 0.002) and right lobes (λ = 1.72 [1.12-2.50] vs 1.13 [0.41-0.43], P = 0.003) and for the PV (λ = 3.15 [2.20-5.00] vs 2.29 [0.85-2.71], P = 0.001). λequilibrium-PVP were significantly different for the right (λ = 0.11 [- 0.45-1.03] vs - 0.44 [- 0.83-0.12], P = 0.045) and left lobe (λ = 0.30 [- 0.25-0.98] vs - 0.10 [- 0.35-0.24], P = 0.001). Significant positive correlations were found between MELD scores and λequilibrium-arterial for the caudate lobe (ρ = 0.34, P = 0.004) and λequilibrium-PVP for the caudate (ρ = 0.26, P = 0.028) and right lobe (ρ = 0.33, P = 0.007). AUROC in distinguishing cirrhotic and non-cirrhotic patients were 0.72 (P = 0.002), 0.71 (P = 0.003), and 0.75 (P = 0.001) using λequilibrium-arterial for the left lobe, right lobe, and PV, respectively. The λequilibrium-PVP AUROC of the right lobe was 0.73 (P = 0.001).

CONCLUSION: Multiphasic DECT iodine quantitation over time is significantly different between cirrhotic and non-cirrhotic patients, correlates with the MELD score, and it could potentially serve as a non-invasive measure of cirrhosis and disease severity with acceptable diagnostic accuracy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Mastrodicasa D, Willemink MJ, Duran C, et al. Non-invasive assessment of cirrhosis using multiphasic dual-energy CT iodine maps: correlation with model for end-stage liver disease score. Abdom Radiol (NY). 2020. PMID: 33211150. doi:10.1007/s00261-020-02857-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。