文献速递腹部技术与安全MR

表观扩散系数值用于神经内分泌肝转移瘤的鉴别

Apparent Diffusion Coefficient Values for Neuroendocrine Liver Metastases.
PubMed 文献 · Acad Radiol · 2020-11-07

研究纳入54例胃肠胰肿瘤肝转移患者共167个病灶,比较胃肠胰神经内分泌肿瘤(GEP-NET)与腺癌肝转移的ADC值,发现GEP-NET组ADC及ADCmean值显著低于腺癌组,ADC与ADCmean的AUC分别为0.733和0.790,提示ADC值可能有助于两者鉴别。

要点

  • 肝转移瘤ADC及ADCmean值较低时提示GEP-NET而非腺癌。
  • ADC鉴别腺癌与GEP-NET转移的AUC为0.733,ADCmean为0.790。
  • ADC cut-off值为933×10-6 mm2/s,ADCmean为801×10-6 mm2/s。

核心结论

  • 肝转移瘤较低的ADC和ADCmean值提示GEP-NET而非腺癌,ADC与ADCmean值可能用于鉴别NET与腺癌。

研究设计与样本

  • 回顾性纳入54例胃肠胰肿瘤肝转移患者共167个肝转移灶,分为GEP-NET组(7例,51个病灶,平均年龄48岁)与腺癌组(47例,116个病灶,平均年龄61.2岁)。
  • 采用独立样本t检验比较两组ADC与ADCmean值,并进行受试者工作特征(ROC)分析。

诊断标准与关键数值

  • GEP-NET组ADC与ADCmean值显著低于腺癌组。
  • ROC分析显示ADC与ADCmean值均有显著差异,AUC分别为0.733和0.790。
  • ADC cut-off值为933×10-6 mm2/s,ADCmean cut-off值为801×10-6 mm2/s。
  • ADC鉴别腺癌转移与GEP-NET转移的敏感度80.2、特异度64.7、PPV 83.8、NPV 58.9。
  • ADCmean鉴别腺癌转移与GEP-NET转移的敏感度63.8、特异度82.4、PPV 89.2、NPV 50。

临床应用与阅片要点

  • 阅片时可测量肝转移瘤的ADC及ADCmean值,较低值提示GEP-NET可能,结合临床与其他影像特征综合判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: We aimed to investigate whether there are any differences in apparent diffusion coefficient (ADC) values obtained from liver metastases due to gastroenteropancreatic neuroendocrine tumors (GEP-NET) and adenocarcinomas.

MATERIALS AND METHODS: We included 54 patients with 167 liver metastases due to gastroenteropancreatic tumors. We divided the patients into two groups as liver metastases due to GEP-NETs (seven patients with 51 lesions, mean age: 48) and adenocarcinomas (47 patients with 116 lesions, mean age: 61.2). We used the independent samples t-test to compare the ADC and ADCmean values of the two groups and performed a receiver-operating characteristic analysis.

RESULTS: ADC and ADCmean values were significantly lower in the GEP-NET group compared with the adenocarcinoma group. Receiver-operating characteristic curve analysis showed a significant difference for ADC and ADCmean values, and area under the curve values were 0.733 and 0.790, respectively. The cut-off values were 933x10-6 mm2/s for ADC and 801x10-6 mm2/s for ADCmean. Diagnostic accuracies of ADC (Sensitivity = 80.2, Specificity = 64.7, PPV = 83.8, NPV = 58.9) and ADCmean (Sensitivity = 63.8, Specificity = 82.4, PPV = 89.2, NPV = 50) were calculated in differentiating adenocarcinoma metastases from GEP-NET metastases.

CONCLUSION: The lower ADC and ADCmean values of liver metastases suggest GEP-NET rather than adenocarcinomas. ADC and ADCmean values obtained from liver metastases may be used to differentiate NETs from adenocarcinomas.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gultekin MA, Turk HM, Yurtsever I, et al. Apparent Diffusion Coefficient Values for Neuroendocrine Liver Metastases. Acad Radiol. 2020. PMID: 33172816. doi:10.1016/j.acra.2020.10.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。