炎症性肠病背景下经皮腹腔脓肿引流累积辐射剂量的影响因素
该单中心回顾性研究纳入炎症性肠病(IBD)接受经皮脓肿引流的患者,分析一次引流 episode(从置管到拔管,含期间所有操作和诊断性 CT)的累积辐射剂量。结果示平均累积有效剂量 47.50 mSv,平均 episode 时长 68.7 天;累积剂量 >50 mSv 者随访次数更多(6.9 vs. 3.5,p=0.003),且更可能需要引流管升级(54% vs. 13%,p=0.01)或额外置管(63% vs. 24%,p=0.03)。作者认为 IBD 脓肿引流可能与显著累积辐射暴露相关。
要点
- 一次 IBD 脓肿引流 episode 平均累积有效剂量达 47.50 mSv,需关注辐射暴露。
- 累积剂量 >50 mSv 者随访次数更多(6.9 vs. 3.5,p=0.003)。
- 累积剂量高者更可能需要引流管升级(54% vs. 13%,p=0.01)或额外置管(63% vs. 24%,p=0.03)。
诊断标准与关键数值
- 一次引流 episode 的平均累积有效剂量为 47.50 mSv,平均 episode 时长为 68.7 天。
- 累积剂量 >50 mSv 组随访次数为 6.9 次,<50 mSv 组为 3.5 次(p=0.003)。
- 累积剂量 >50 mSv 组引流管升级比例为 54%,<50 mSv 组为 13%(p=0.01)。
- 累积剂量 >50 mSv 组额外置管比例为 63%,<50 mSv 组为 24%(p=0.03)。
临床应用与阅片要点
- 对 IBD 脓肿引流患者,应将引流 episode 期间所有介入操作和诊断性 CT 计入累积辐射剂量评估。
- 累积剂量 >50 mSv 者随访次数更多、更可能需要引流管升级或额外置管。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Patients with inflammatory bowel disease (IBD) are at risk for intra-abdominal abscesses requiring CT-guided drainage. These patients are at baseline risk of high cumulative radiation exposure from imaging, which may be exacerbated by CT-guided drainage. This study aimed to determine the radiation dose associated with percutaneous drainage in the setting of IBD and identify risk factors associated with high exposure.
METHODS: An IRB-approved single-center retrospective study was performed to identify patients with IBD who underwent percutaneous abscess drainage over a 5-year period. An episode of drainage was defined from drain placement to removal, with all intervening procedures and diagnostic CT scans included in the cumulative radiation dose.
RESULTS: The mean cumulative effective dose for a drainage episode was 47.50 mSv. The mean duration of a drainage episode was 68.7 days. Patients with a cumulative dose greater than 50 mSv required higher number of follow-up visits compared to patients with less than 50 mSv (6.9 vs. 3.5, p = 0.003*). Patients with higher cumulative dose were also more likely to require drain upsize (54% vs. 13%, p = 0.01*) or additional drain placement (63% vs 24%, p = 0.03*) compared to patients with lower dose.
CONCLUSION: Intra-abdominal abscess drainage may be associated with significant cumulative radiation exposure. Requirement of drain upsizing or additional drain placement were associated with higher cumulative radiation dose, which may be related to more severe underlying inflammatory bowel disease.
引用
- An TJ, Tabari A, Gee MS, et al. Factors influencing cumulative radiation dose from percutaneous intra-abdominal abscess drainage in the setting of inflammatory bowel disease. Abdom Radiol (NY). 2020. PMID: 33237341. doi:10.1007/s00261-020-02864-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。