文献速递腹部骨肌CTMR

磁共振成像测量腹部骨骼肌面积的可靠性与有效性

Reliability and Validity of Abdominal Skeletal Muscle Area Measurement Using Magnetic Resonance Imaging.
PubMed 文献 · Acad Radiol · 2020-10-29

本研究以32例肾病患者为对象,比较CT与基于IDEAL-IQ序列脂肪图像的MRI在L3椎体中部水平测量腹部骨骼肌面积(SMA)的一致性与可重复性。结果显示MRI观察者间可靠性优秀(CV 2.82%,ICC 0.996–0.999),与CT一致性高(CV 1.7%,ICC 0.986–0.996,平均差异2.2%,r=0.995,p<0.0001)。

要点

  • MRI脂肪图像测量腹部SMA与CT高度一致,平均差异仅2.2%,相关系数0.995。
  • MRI观察者间ICC为0.996–0.999,CV为2.82%,可重复性优秀。
  • MRI与CT效度比较ICC为0.986–0.996,CV为1.7%,支持MRI用于SMA定量。

核心结论

  • MRI在腹部SMA定量中表现出良好的观察者间可靠性和与CT的极好一致性。

研究设计与样本

  • 研究纳入32例确诊各种肾脏疾病的患者,使用CT和MRI图像分析腹部SMA测量的观察者内变异性。
  • MRI采用IDEAL-IQ序列脂肪图像,测量层面为L3椎体中部水平,图像分割使用Materialise Mimics软件。
  • 由两名独立研究者评估观察者间可靠性和测量有效性,采用ICC、CV、Bland-Altman图和Pearson相关系数进行统计分析。

关键影像表现/征象

  • 原文未报告影像征象描述,仅涉及SMA定量测量。

诊断标准与关键数值

  • MRI观察者间可靠性:CV为2.82%,ICC范围为0.996–0.999。
  • MRI与CT效度:CV为1.7%,ICC范围为0.986–0.996。
  • Bland-Altman分析显示MRI与CT平均差异为2.2%;Pearson相关系数为0.995(p<0.0001)。

临床应用与阅片要点

  • 基于IDEAL-IQ序列脂肪图像测量L3椎体中部水平腹部SMA与CT一致性高,可用于骨骼肌质量评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Skeletal muscle mass measurement is the most important element for diagnosing sarcopenia. MRI has an excellent soft-tissue contrast, which can non-invasively assess abdominal skeletal muscle area (SMA) as well as CT. This study aimed to assess the validity and reliability of abdominal SMA measurement by comparing CT and MRI based on the fat image of IDEAL-IQ sequence at the lumbar level mid-L3.

MATERIALS AND METHODS: CT and MRI images of 32 patients diagnosed with various kidney diseases were used to analyze intra-observer variability among abdominal SMA measurements. This was done to evaluate the correlation of SMA between CT and fat images of MRI. SMA images were segmented using Materialise Mimics software before quantification. Interobserver reliability and validation of measurements was evaluated by two independent investigators. Abdominal SMA reproducibility and correlation between CT and MRI were then assessed using the intraclass correlation coefficient (ICC), coefficient of variation (CV), Bland-Altman plot, and Pearson's correlation coefficient respectively.

RESULTS: The interobserver reliability of MRI was excellent. The CV value was 2.82% while the ICC values ranged between 0.996 and 0.999. Validity was high (CV was 1.7% and ICC ranged between 0.986 and 0.996) for measurements by MRI and CT. Bland Altman analysis revealed an average difference of 2.2% between MRI and CT. The Pearson's correlation coefficient was 0.995 (p < 0.0001). This result revealed that there was a strong correlation between the two technologies.

CONCLUSION: MRI exhibited good interobserver reliability and excellent agreement with CT for quantification of abdominal SMA.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang FZ, Sun H, Zhou J, et al. Reliability and Validity of Abdominal Skeletal Muscle Area Measurement Using Magnetic Resonance Imaging. Acad Radiol. 2020. PMID: 33129660. doi:10.1016/j.acra.2020.09.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。