系统性硬化症患者肺动脉血流动力学的早期改变:基于4D flow MRI的血流模式、WSS与OSI分析
本研究用4D flow MRI对比23例系统性硬化症患者(其中3例经右心导管证实为显性肺动脉高压)与10名对照者的肺动脉血流动力学,发现患者舒张期最小血流、振荡剪切指数(OSI)显著增高而收缩期峰值壁面剪切应力(WSS)显著降低;主肺动脉最小血流≤9.22 ml/s及雷诺数≤2560的患者复合终点无事件生存率显著更低。
要点
- SSc患者舒张期主肺动脉最小血流高于对照(7.7±16.0 ml/s vs -13.0±17.3 ml/s,p<0.01)。
- SSc患者收缩期峰值WSS低于对照、OSI高于对照,均p<0.01。
- 主肺动脉最小血流≤9.22 ml/s或雷诺数≤2560者复合终点无事件生存率更低。
关键影像表现/征象
- 收缩期肺动脉最大血流在两组间无差异,但舒张期最小血流在SSc患者显著大于对照(7.7±16.0 ml/s vs -13.0±17.3 ml/s,p<0.01)。
- 收缩期峰值最大WSS在SSc患者显著低于对照(1.04±0.20 Pa vs 1.33±0.34 Pa,p<0.01)。
- OSI在SSc患者显著大于对照(0.139±0.031 vs 0.101±0.037,p<0.01)。
诊断标准与关键数值
- 主肺动脉最小血流≤9.22 ml/s的SSc患者复合终点累积无事件率显著更低(p=0.012)。
- 雷诺数≤2560的SSc患者复合终点累积无事件率显著更低(p<0.001)。
临床应用与阅片要点
- 4D flow MRI可在显性肺动脉高压出现前检出SSc患者肺动脉血流动力学改变,包括舒张期最小血流升高、收缩期峰值WSS降低与OSI升高。
- 主肺动脉最小血流与雷诺数可能作为SSc的预测指标,用于患者管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To study the pulmonary artery (PA) hemodynamics in patients with systemic sclerosis (SSc) using 4D flow MRI (4D-flow).
METHODS: Twenty-three patients with SSc (M/F: 2/21, 57 ± 15 years, 3 manifest PA hypertension (PAH) by right heart catheterization) and 10 control subjects (M/F: 1/9, 55 ± 17 years) underwent 4D-flow for the in vivo measurement of 3D blood flow velocities in the PA. Data analysis included area-averaged flow quantification at the main PA, 3D wall shear stress (WSS), oscillatory shear index (OSI) calculation along the PA surface, and Reynolds number. The composite outcome of all-cause death and major adverse cardiac events was also investigated.
RESULTS: The maximum PA flow at the systole did not differ, but the minimum flow at the diastole was significantly greater in patients with SSc compared with that in control subjects (7.7 ± 16.0 ml/s vs. ‑ 13.0 ± 17.3 ml/s, p < 0.01). The maximum WSS at the peak systole was significantly lower and OSI was significantly greater in patients with SSc compared with those in control subjects (maximum WSS: 1.04 ± 0.20 Pa vs. 1.33 ± 0.34 Pa, p < 0.01, OSI: 0.139 ± 0.031 vs. 0.101 ± 0.037, p < 0.01). The cumulative event-free rate for the composite event was significantly lower in patients with minimum flow in main PA ≤ 9.22 ml/s (p = 0.012) and in patients with Reynolds number ≤ 2560 (p < 0.001).
CONCLUSIONS: 4D-flow has the potential to detect changes of PA hemodynamics noninvasively and predict the outcome in patients with SSc at the stage before manifest PAH.
KEY POINTS: • The WSS at the peak systolic phase was significantly lower (p < 0.05), whereas OSI was greater (p < 0.01) in patients with SSc without manifest PAH than in controls. • The hemodynamic change detected by 4D-flow may help patient management even at the stage before manifest PAH in SSc. • The minimum PA flow and Reynolds number by 4D-flow will serve as a predictive marker for SSc.
引用
- Ikoma T, Suwa K, Sano M, et al. Early changes of pulmonary arterial hemodynamics in patients with systemic sclerosis: flow pattern, WSS, and OSI analysis with 4D flow MRI. Eur Radiol. 2020. PMID: 33211148. doi:10.1007/s00330-020-07301-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。