文献速递心血管外周血管胸部MRUS

球囊肺动脉成形术逆转不可手术慢性血栓栓塞性肺动脉高压患者的右心室重构与功能障碍:系统评价与荟萃分析

Balloon pulmonary angioplasty reverse right ventricular remodelling and dysfunction in patients with inoperable chronic thromboembolic pulmonary hypertension: a systematic review and meta-analysis.
PubMed 文献 · Eur Radiol · 2020-11-17

该系统评价与荟萃分析纳入10项研究共299例不可手术或肺动脉内膜切除术后持续/复发性肺动脉高压的慢性血栓栓塞性肺动脉高压患者,评估球囊肺动脉成形术前后心脏磁共振和/或超声心动图测量的右心室功能。结果显示球囊肺动脉成形术可改善右心室射血分数并降低右心室容积,但三尖瓣环收缩期位移和S'改善不显著。

要点

  • 球囊肺动脉成形术可显著降低右心室舒张末期容积指数和收缩末期容积指数,并提高右心室射血分数。
  • 超声心动图显示右心室基底段内径减小、右心室面积变化分数增加,但三尖瓣环收缩期位移和S'改善不显著。
  • 心脏磁共振和超声心动图均可用于评估球囊肺动脉成形术后的右心室逆转重构。

诊断标准与关键数值

  • 心脏磁共振汇总数据显示球囊肺动脉成形术后右心室舒张末期容积指数加权均数差为-28.33 ml/m2(p < 0.00001),右心室收缩末期容积指数加权均数差为-29.06 ml/m2(p < 0.00001),右心室射血分数加权均数差为8.97%(p < 0.00001)。
  • 超声心动图汇总数据显示球囊肺动脉成形术后右心室基底段内径加权均数差为-0.37 cm(p = 0.0009),右心室面积变化分数加权均数差为5.97%(p = 0.003)。
  • 超声心动图显示三尖瓣环收缩期位移和S'的改善不显著。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Right ventricular (RV) function is considered the major determinant of prognosis in patients with chronic thromboembolic pulmonary hypertension (CTEPH). The aim of this meta-analysis was to evaluate RV remodelling and function following balloon pulmonary angioplasty (BPA) in patients with inoperable CTEPH or persistent/recurrent pulmonary hypertension (PH) after pulmonary endarterectomy (PEA).

METHODS: We reviewed all studies evaluating RV function by cardiac magnetic resonance (CMR) and/or echocardiography pre- and post-BPA from PubMed/Medline prior to 15 December 2019. Ten (299 patients) of the 29 studies retrieved met the inclusion criteria: 5 CMR and 5 echocardiography studies. The systematic review and meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Guidelines.

RESULTS: Pooled data from CMR studies revealed BPA resulted in a significantly decreased RV end-diastolic volume index (weighted mean difference (WMD) - 28.33 ml/m2, p < 0.00001) and RV end-systolic volume index (WMD - 29.06 ml/m2, p < 0.00001) accompanied by an increased RV ejection fraction (RVEF, WMD 8.97%, p < 0.00001). Data from the echocardiography studies showed BPA resulted in decreased RV basal diameter (WMD - 0.37 cm, p = 0.0009) and an increase of RV fractional area change (WMD 5.97 %, p = 0.003), but improvements of tricuspid annular plane systolic excursion (TAPSE) and S' were not significant.

CONCLUSIONS: BPA improves RVEF and decreases RV volumes in patients with inoperable CTEPH or persistent/recurrent PH after PEA.

KEY POINTS: • Balloon pulmonary angioplasty improves RVEF and decreases RV volumes in patients with inoperable CTEPH or persistent/recurrent PH after PEA.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li W, Yang T, Quan RL, et al. Balloon pulmonary angioplasty reverse right ventricular remodelling and dysfunction in patients with inoperable chronic thromboembolic pulmonary hypertension: a systematic review and meta-analysis. Eur Radiol. 2020. PMID: 33201287. doi:10.1007/s00330-020-07481-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。