文献速递心血管MR

心房颤动导管消融后左心耳隔离的心脏磁共振评估:心耳储备的悖论

Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir.
PubMed 文献 · Korean J Radiol · 2020-11-19

本研究回顾性纳入84例心房颤动成功导管消融后行心脏磁共振的患者,根据左心耳电活动分为左心耳隔离组(23例)与左心耳正常活动组(61例)。左心耳隔离组收缩期出现左心耳排空的比例显著更高(91% vs. 0%,p < 0.001),左心耳排空通量(40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s,p < 0.001)及左心房射血分数(23.7% ± 11.2% vs. 31.1% ± 16.6%,p = 0.04)均显著低于左心耳正常活动组。多变量分析显示左心耳排空时相独立于左心房射血分数(p = 0.01)。作者认为收缩期左心耳排空可能是左心耳隔离的关键特征,并可能对消融后左心房射血分数产生不利影响。

要点

  • 房颤消融后左心耳隔离患者中91%出现收缩期左心耳排空,而左心耳正常活动组为0%。
  • 左心耳隔离组左心耳排空通量40.1 ± 16.2 mL/s,显著低于正常活动组的80.2 ± 25.1 mL/s(p < 0.001)。
  • 左心耳隔离组左心房射血分数23.7% ± 11.2%,显著低于正常活动组的31.1% ± 16.6%(p = 0.04)。

关键影像表现/征象

  • 左心耳隔离组收缩期出现左心耳排空的比例为91%,左心耳正常活动组为0%(p < 0.001)。
  • 左心耳隔离组左心耳排空通量为40.1 ± 16.2 mL/s,左心耳正常活动组为80.2 ± 25.1 mL/s(p < 0.001)。
  • 左心耳隔离组左心房射血分数为23.7% ± 11.2%,左心耳正常活动组为31.1% ± 16.6%(p = 0.04)。

诊断标准与关键数值

  • 左心耳排空时相分为收缩期与舒张期,由心脏磁共振评估。
  • 左心耳排空通量以mL/s表示,左心房射血分数以%表示。

临床应用与阅片要点

  • 心脏磁共振评估左心耳排空时相、左心耳排空通量及左心房射血分数,可用于识别房颤消融后左心耳隔离患者。
  • 左心耳隔离患者中收缩期左心耳排空常见,且左心耳排空通量与左心房射血分数均低于左心耳正常活动者。
  • 多变量分析显示左心耳排空时相独立于左心房射血分数(p = 0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the effect of left atrial appendage (LAA) isolation on LAA emptying and left atrial (LA) function using cardiac MRI in patients who underwent successful catheter ablation of atrial fibrillation (AF).

MATERIALS AND METHODS: This retrospective study included 84 patients (mean age, 59 ± 10 years; 67 males) who underwent cardiac MRI after successful catheter ablation of AF. According to the electrical activity of LAA after catheter ablation, patients showed either LAA isolation or LAA normal activity. The LAA emptying phase (LAA-EP, in the systolic phase [SP] or diastolic phase), LAA emptying flux (LAA-EF, mL/s), and LA ejection fraction (LAEF, %) were evaluated by cardiac MRI.

RESULTS: Of the 84 patients, 61 (73%) and 23 (27%) patients showed LAA normal activity and LAA isolation, respectively. Incidence of LAA emptying in SP was significantly higher in LAA isolation (91% vs. 0%, p < 0.001) than in LAA normal activation. LAA-EF was significantly lower in LAA isolation (40.1 ± 16.2 mL/s vs. 80.2 ± 25.1 mL/s, p < 0.001) than in LAA normal activity. Furthermore, LAEF was significantly lower in LAA isolation (23.7% ± 11.2% vs. 31.1% ± 16.6%, p = 0.04) than in LAA normal activity. Multivariate analysis demonstrated that the LAA-EP was independent from LAEF (p = 0.01).

CONCLUSION: LAA emptying in SP may be a critical characteristic of LAA isolation, and it may adversely affect the LAEF after catheter ablation of AF.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Cho H, Cho Y, Shim J, et al. Evaluation of Left Atrial Appendage Isolation Using Cardiac MRI after Catheter Ablation of Atrial Fibrillation: Paradox of Appendage Reservoir. Korean J Radiol. 2020. PMID: 33236545. doi:10.3348/kjr.2020.0629

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。