文献速递心血管外周血管CT

高螺距双源CT评估经导管主动脉瓣置换术主动脉瓣环尺寸:收缩期高螺距与多时相数据采集的比较

Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition.
PubMed 文献 · Eur J Radiol · 2020-10-24

本研究回顾性纳入61例TAVI患者,对比收缩期心电门控高螺距主动脉髂动脉CTA与多时相心电门控心脏CTA测量主动脉瓣环面积及假想假体尺寸选择。高螺距与多时相CT的AAA强相关(r=0.98),差值10.5±17.1 mm²未达统计学显著(p=0.08),假体尺寸选择一致率90.2%,6例不一致者均为心房颤动患者。高螺距CTA平均有效辐射剂量4.1±1.0 mSv,心脏CTA为10.9±6.1 mSv。

要点

  • 高螺距与多时相CT测得的主动脉瓣环面积强相关(r=0.98),差值未达统计学显著。
  • 假体尺寸选择一致率为90.2%(55/61),不一致的6例均为心房颤动患者。
  • 高螺距CTA有效辐射剂量4.1±1.0 mSv,心脏CTA为10.9±6.1 mSv。

诊断标准与关键数值

  • 高螺距与多时相CT测得的主动脉瓣环面积强相关,r=0.98。
  • 主动脉瓣环面积多时相CT为455.1±83.0 mm²,高螺距CT为444.5±87.2 mm²,差值10.5±17.1 mm²,p=0.08。
  • 基于两种CT的假想假体尺寸选择一致率为90.2%(55/61)。
  • 6例假体尺寸选择不一致者均患心房颤动,高螺距CT导致选择更小的假体。

临床应用与阅片要点

  • 作者结论认为,窦性心律患者可采用收缩期高螺距主动脉髂动脉CTA进行TAVI术前假体尺寸选择。
  • 高螺距CTA平均有效辐射剂量4.1±1.0 mSv,心脏CTA为10.9±6.1 mSv。
  • 患者平均心率71.0±13.4 bpm,心率变异性7.3±8.5 bpm;32.7%(20/61)患者图像采集时存在心房颤动。

局限性

  • 本研究为回顾性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate a systolic ECG-gated high-pitch aortoiliac computed tomography (CT) angiography for planning transcatheter aortic valve implantation (TAVI).

METHODS: Patients referred for TAVI underwent a combined CT imaging with retrospective, multiphasic ECG-gating of the heart and systolic ECG-gated high-pitch aortoiliac CT angiography. Consecutive patients were retrospectively included in this study group. Heart rate (HR) and heart rate variability (HRV) were assessed during the high-pitch ECG prediction phase. Aortic annulus area (AAA) was planimetrically quantified on both datasets. While only one moment of cardiac cycle was available for measurements in the high-pitch CT, the point of time in the multiphasic CT was chosen, where AAA yielded maximum size. Hypothetical prosthesis sizing was compared between multiphasic vs. high-pitch CT.

RESULTS: Among 61 patients (44.2 % men, mean age: 83.3 ± 5.5 years) average heart rate and HRV were 71.0 ± 13.4 bpm and 7.3 ± 8.5 bpm. 20 patients (32.7 %) had atrial fibrillation at the time of image acquisition. There was a strong correlation of AAA as derived from multiphasic vs. the high-pitch CT (r = 0.98). The difference in AAA was 10.5 ± 17.1mm2 (455.1 ± 83.0 mm2 for multiphasic vs. 444.5 ± 87.2 mm2 for high-pitch CT) and did not reach statistical significance (p = 0.08). Hypothetical prosthesis sizing showed an agreement in 55 of 61 patients (90.2 %). A sizing based on the high-pitch CT resulted in smaller prosthesis choice in 6 patients, all of them suffering from atrial fibrillation. Mean effective radiation dose was 10.9 ± 6.1 mSv for cardiac CTA and 4.1 ± 1.0 mSv for high-pitch CTA.

CONCLUSION: For patients with sinus rhythm, systolic high-pitch aortoiliac CTA provides adequate prosthesis size selection as compared with multiphasic ECG-gated cardiac CTA and may result in significantly reduced radiation exposition.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Capilli F, Benndorf M, Soschynski M, et al. Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition. Eur J Radiol. 2020. PMID: 33166834. doi:10.1016/j.ejrad.2020.109366

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。