三维深度卷积神经网络用于B型主动脉夹层的自动分割与直径测量
连续收集139例B型主动脉夹层患者的主动脉CT血管造影图像,采用基于三维深度卷积神经网络的方法自动分割并测量整个主动脉、真腔和假腔,并与人工方法比较准确性、稳定性和测量时间。深度学习组平均测量误差低于人工组,测量时间明显缩短,观察者内和观察者间差异仅见于人工方法。
要点
- 三维深度卷积神经网络可自动分割B型主动脉夹层的整个主动脉、真腔和假腔,平均Dice系数分别为0.958、0.961和0.932。
- 深度学习组平均测量误差低于人工组:整个主动脉1.64% vs 4.13%,真腔2.46% vs 11.67%,假腔2.50% vs 8.02%。
- 深度学习测量时间明显短于人工方法:21.7±1.1 vs 82.5±16.1分钟,P<0.001。
诊断标准与关键数值
- 整个主动脉、真腔和假腔的平均Dice系数分别为0.958、0.961和0.932。
- 参考标准与人工测量及深度学习测量均呈线性关系,r分别为0.964和0.991。
- 深度学习组平均测量误差:整个主动脉1.64%、真腔2.46%、假腔2.50%;人工组对应为整个主动脉4.13%、真腔11.67%、假腔8.02%。
- Bland-Altman分析显示深度学习法与参考标准的直径偏差:整个主动脉-0.042 mm(-3.412至3.330 mm)、真腔-0.376 mm(-3.328至2.577 mm)、假腔0.026 mm(-3.040至3.092 mm)。
- 人工法对应偏差:整个主动脉-0.166 mm(-1.419至1.086 mm)、真腔-0.050 mm(-0.970至1.070 mm)、假腔-0.085 mm(-1.010至0.084 mm)。
临床应用与阅片要点
- 深度学习法测量时间明显短于人工法(21.7±1.1 vs 82.5±16.1分钟,P<0.001)。
- 人工法测量存在观察者内和观察者间差异,深度学习法未见观察者内和观察者间差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To provide an automatic method for segmentation and diameter measurement of type B aortic dissection (TBAD).
MATERIALS AND METHODS: Aortic computed tomography angiographic images from 139 patients with TBAD were consecutively collected. We implemented a deep learning method based on a three-dimensional (3D) deep convolutional neural (CNN) network, which realizes automatic segmentation and measurement of the entire aorta (EA), true lumen (TL), and false lumen (FL). The accuracy, stability, and measurement time were compared between deep learning and manual methods. The intra- and inter-observer reproducibility of the manual method was also evaluated.
RESULTS: The mean dice coefficient scores were 0.958, 0.961, and 0.932 for EA, TL, and FL, respectively. There was a linear relationship between the reference standard and measurement by the manual and deep learning method (r = 0.964 and 0.991, respectively). The average measurement error of the deep learning method was less than that of the manual method (EA, 1.64% vs. 4.13%; TL, 2.46% vs. 11.67%; FL, 2.50% vs. 8.02%). Bland-Altman plots revealed that the deviations of the diameters between the deep learning method and the reference standard were -0.042 mm (-3.412 to 3.330 mm), -0.376 mm (-3.328 to 2.577 mm), and 0.026 mm (-3.040 to 3.092 mm) for EA, TL, and FL, respectively. For the manual method, the corresponding deviations were -0.166 mm (-1.419 to 1.086 mm), -0.050 mm (-0.970 to 1.070 mm), and -0.085 mm (-1.010 to 0.084 mm). Intra- and inter-observer differences were found in measurements with the manual method, but not with the deep learning method. The measurement time with the deep learning method was markedly shorter than with the manual method (21.7 ± 1.1 vs. 82.5 ± 16.1 minutes, p < 0.001).
CONCLUSION: The performance of efficient segmentation and diameter measurement of TBADs based on the 3D deep CNN was both accurate and stable. This method is promising for evaluating aortic morphology automatically and alleviating the workload of radiologists in the near future.
引用
- Yu Y, Gao Y, Wei J, et al. A Three-Dimensional Deep Convolutional Neural Network for Automatic Segmentation and Diameter Measurement of Type B Aortic Dissection. Korean J Radiol. 2020. PMID: 33236538. doi:10.3348/kjr.2020.0313
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。