文献速递心血管外周血管IVUS

无标记可视化与定量分析动脉粥样硬化斑块进展的生化标志物:血管内荧光寿命成像研究

Label-Free Visualization and Quantification of Biochemical Markers of Atherosclerotic Plaque Progression Using Intravascular Fluorescence Lifetime.
PubMed 文献 · JACC Cardiovasc Imaging · 2020-11-18

研究采用血管内荧光寿命成像(FLIm)联合血管内超声的双模态导管系统,对32段人冠状动脉进行分析,共204张组织学切片、33,980个测量点,评估荧光寿命与斑块表层组织学成分的关系。结果显示不同光谱通道的荧光寿命可定量预测巨噬细胞泡沫细胞(AUC 0.94)、检测表层钙化(AUC 0.90),并可能识别与活动性斑块形成一致的病变。

要点

  • 540 nm波段荧光寿命可定量预测斑块表层巨噬细胞泡沫细胞,AUC为0.94。
  • 450 nm波段荧光寿命降低可检测表层钙化,AUC为0.90。
  • 390 nm波段荧光寿命升高可能识别与活动性斑块形成一致的病变,如病理性内膜增厚和愈合血栓区域。

核心结论

  • 自身荧光寿命可为冠状动脉粥样硬化病变表征提供有价值的信息,FLIm可识别与斑块进展相关的关键现象,如富含过氧化脂质的巨噬细胞泡沫细胞积聚和近期斑块形成。

研究设计与样本

  • 研究论文;人冠状动脉节段n=32,组织学切片n=204,测量位置n=33,980;采用结合多光谱FLIm与血管内超声的双模态导管系统,超声形态学信息用于影像与组织学的准确配准;参考标准为组织学。

诊断标准与关键数值

  • 荧光寿命预测表层巨噬细胞泡沫细胞的AUC为0.94;540 nm波段荧光寿命升高提示进展期病变中细胞外脂质含量;450 nm波段荧光寿命降低检测表层钙化的AUC为0.90;390 nm波段荧光寿命升高可能检测与活动性斑块形成一致的病变,如病理性内膜增厚和愈合血栓区域。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to systematically investigate whether plaque autofluorescence properties assessed with intravascular fluorescence lifetime imaging (FLIm) can provide qualitative and quantitative information about intimal composition and improve the characterization of atherosclerosis lesions.

BACKGROUND: Despite advances in cardiovascular diagnostics, the analytic tools and imaging technologies currently available have limited capabilities for evaluating in situ biochemical changes associated with luminal surface features. Earlier studies of small number of samples have shown differences among the autofluorescence lifetime signature of well-defined lesions, but a systematic pixel-level evaluation of fluorescence signatures associated with various histological features is lacking and needed to better understand the origins of fluorescence contrast.

METHODS: Human coronary artery segments (n = 32) were analyzed with a bimodal catheter system combining multispectral FLIm with intravascular ultrasonography compatible with in vivo coronary imaging. Various histological components present along the luminal surface (200-μm depth) were systematically tabulated (12 sectors) from each serial histological section (n = 204). Morphological information provided by ultrasonography allowed for the accurate registration of imaging data with histology data. The relationships between histological findings and FLIm parameters obtained from 3 spectral channels at each measurement location (n = 33,980) were characterized.

RESULTS: Our findings indicate that fluorescence lifetime from different spectral bands can be used to quantitatively predict the superficial presence of macrophage foam cells (mFCs) (area under the receiver-operator characteristic curve: 0.94) and extracellular lipid content in advanced lesions (lifetime increase in 540-nm band), detect superficial calcium (lifetime decrease in 450-nm band area under the receiver-operator characteristic curve: 0.90), and possibly detect lesions consistent with active plaque formation such as pathological intimal thickening and healed thrombus regions (lifetime increase in 390-nm band).

CONCLUSIONS: Our findings indicate that autofluorescence lifetime provides valuable information for characterizing atherosclerotic lesions in coronary arteries. Specifically, FLIm can be used to identify key phenomena linked with plaque progression (e.g., peroxidized-lipid-rich mFC accumulation and recent plaque formation).

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Bec J, Vela D, Phipps JE, et al. Label-Free Visualization and Quantification of Biochemical Markers of Atherosclerotic Plaque Progression Using Intravascular Fluorescence Lifetime. JACC Cardiovasc Imaging. 2020. PMID: 33221238. doi:10.1016/j.jcmg.2020.10.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。