文献速递心血管胸部CT

冠状动脉CT血管成像中心肌与心包脂肪的自动定量:一项多中心研究

Automatic quantification of myocardium and pericardial fat from coronary computed tomography angiography: a multicenter study.
PubMed 文献 · Eur Radiol · 2020-11-18

本研究基于六中心2008年5月至2018年7月回顾性CCTA数据,开发深度学习法同步定量心肌与心包脂肪,在422例患者中采用跨疾病状态和留中心法评估。自动分割与轮廓高度相关(ICC和R>0.97,p<0.001),心包脂肪中位DSC>0.88、心肌>0.96。

要点

  • 深度学习法可在多中心CCTA上同步自动分割心肌与心包脂肪,中位DSC心包脂肪>0.88、心肌>0.96。
  • 自动分割与人工轮廓高度相关,所有测试ICC和R>0.97(p<0.001)。
  • 心包脂肪平均MSD、RMSD、HD95和CMD<1.36 mm,心肌<1.00 mm。

诊断标准与关键数值

  • 自动分割与轮廓相关性ICC和R>0.97(所有测试p<0.001)。
  • 心包脂肪中位DSC>0.88,心肌中位DSC>0.96。
  • 心包脂肪平均MSD、RMSD、HD95和CMD<1.36 mm,心肌<1.00 mm。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a deep learning-based method for simultaneous myocardium and pericardial fat quantification from coronary computed tomography angiography (CCTA) for the diagnosis and treatment of cardiovascular disease (CVD).

METHODS: We retrospectively identified CCTA data obtained between May 2008 and July 2018 in a multicenter (six centers) CVD study. The proposed method was evaluated on 422 patients' data by two studies. The first overall study involves training model on CVD patients and testing on non-CVD patients, as well as training on non-CVD patients and testing on CVD patients. The second study was performed using the leave-center-out approach. The method performance was evaluated using Dice similarity coefficient (DSC), Jaccard index (JAC), 95% Hausdorff distance (HD95), mean surface distance (MSD), residual mean square distance (RMSD), and the center of mass distance (CMD). The robustness of the proposed method was tested using the nonparametric Kruskal-Wallis test and post hoc test to assess the equality of distribution of DSC values among different tests.

RESULTS: The automatic segmentation achieved a strong correlation with contour (ICC and R > 0.97, p value < 0.001 throughout all tests). The accuracy of the proposed method remained high through all the tests, with the median DSC higher than 0.88 for pericardial fat and 0.96 for myocardium. The proposed method also resulted in mean MSD, RMSD, HD95, and CMD of less than 1.36 mm for pericardial fat and 1.00 mm for myocardium.

CONCLUSIONS: The proposed deep learning-based segmentation method enables accurate simultaneous quantification of myocardium and pericardial fat in a multicenter study.

KEY POINTS: • Deep learning-based myocardium and pericardial fat segmentation method tested on 422 patients' coronary computed tomography angiography in a multicenter study. • The proposed method provides segmentations with high volumetric accuracy (ICC and R > 0.97, p value < 0.001) and similar shape as manual annotation by experienced radiologists (median Dice similarity coefficient ≥ 0.88 for pericardial fat and 0.96 for myocardium).

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. He X, Guo BJ, Lei Y, et al. Automatic quantification of myocardium and pericardial fat from coronary computed tomography angiography: a multicenter study. Eur Radiol. 2020. PMID: 33206226. doi:10.1007/s00330-020-07482-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。