文献速递心血管外周血管IVUSOCT

NIRS-IVUS鉴别急性心肌梗死中冠状动脉斑块破裂、侵蚀与钙化结节

NIRS-IVUS for Differentiating Coronary Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction.
PubMed 文献 · JACC Cardiovasc Imaging · 2020-11-18

研究纳入244例急性心肌梗死患者,以OCT诊断为参考标准,评估NIRS-IVUS鉴别斑块破裂、斑块侵蚀与钙化结节的能力。验证队列中,基于斑块腔、凸起钙化和maxLCBI4mm的分类算法对三者识别的敏感度和特异度分别为97%和96%、93%和99%、100%和99%。

要点

  • IVUS检测斑块腔识别OCT斑块破裂特异度100%、敏感度62%。
  • IVUS检测凸起钙化识别OCT钙化结节敏感度93%、特异度100%。
  • 验证队列NIRS-IVUS算法识别斑块破裂、侵蚀、钙化结节的敏感度97%、93%、100%。

关键影像表现/征象

  • IVUS检测的斑块腔对OCT斑块破裂显示高特异度(100%)和中等敏感度(62%)。
  • IVUS检测的凸起钙化对OCT钙化结节显示高敏感度(93%)和特异度(100%)。
  • NIRS测量的maxLCBI4mm在OCT斑块破裂中最大(705,IQR 545-854),其次为OCT钙化结节(355,IQR 303-478)和OCT斑块侵蚀(300,IQR 126-357),P<0.001。

诊断标准与关键数值

  • maxLCBI4mm鉴别OCT斑块破裂与斑块侵蚀的最佳截断值为426。
  • maxLCBI4mm鉴别OCT斑块侵蚀与钙化结节的最佳截断值为328。
  • maxLCBI4mm鉴别OCT斑块破裂与钙化结节的最佳截断值为579。
  • 验证队列中,NIRS-IVUS分类算法(联合斑块腔、凸起钙化和maxLCBI4mm)识别OCT斑块破裂的敏感度和特异度分别为97%和96%。
  • 验证队列中,该算法识别OCT斑块侵蚀的敏感度和特异度分别为93%和99%,识别OCT钙化结节的敏感度和特异度分别为100%和99%。

临床应用与阅片要点

  • 阅片时可结合IVUS斑块腔(高特异度)和凸起钙化(高敏感度)征象,并参考maxLCBI4mm截断值辅助区分斑块破裂、侵蚀与钙化结节。
  • 作者结论认为NIRS-IVUS通过评估斑块腔、凸起钙化和maxLCBI4mm可准确鉴别斑块破裂、斑块侵蚀和钙化结节。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to investigate the ability of combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) to differentiate plaque rupture (PR), plaque erosion (PE), or calcified nodule (CN) in acute myocardial infarction (AMI).

BACKGROUND: Most acute coronary syndromes occur from coronary thrombosis based on PR, PE, or CN. In vivo differentiation among PR, PE, and CN is a major challenge for intravascular imaging.

METHODS: The study enrolled 244 patients with AMI who had a de novo culprit lesion in a native coronary artery. The culprit lesions were assessed by both NIRS-IVUS and optical coherence tomography (OCT). Maximum lipid core burden index in 4 mm (maxLCBI4mm) was measured by NIRS. Plaque cavity and convex calcium was detected by IVUS. The OCT diagnosis of PR (n = 175), PE (n = 44), and CN (n = 25) was used as a reference standard.

RESULTS: In the development cohort, IVUS-detected plaque cavity showed a high specificity (100%) and intermediate sensitivity (62%) for identifying OCT-PR. IVUS-detected convex calcium showed a high sensitivity (93%) and specificity (100%) for identifying OCT-CN. NIRS-measured maxLCBI4mm was largest in OCT-PR (705 [interquartile range (IQR): 545 to 854]), followed by OCT-CN (355 [IQR: 303 to 478]) and OCT-PE (300 [IQR: 126 to 357]) (p < 0.001). The optimal cutoff value of maxLCBI4mm was 426 for differentiating between OCT-PR and -PE; 328 for differentiating between OCT-PE and -CN; and 579 for differentiating between OCT-PR and -CN. In the validation cohort, the NIRS-IVUS classification algorithm using plaque cavity, convex calcium, and maxLCBI4mm showed a sensitivity and specificity of 97% and 96% for identifying OCT-PR, 93% and 99% for OCT-PE, and 100% and 99% for OCT-CN, respectively.

CONCLUSIONS: By evaluating plaque cavity, convex calcium, and maxLCBI4mm, NIRS-IVUS can accurately differentiate PR, PE, and CN.