高分辨率心脏磁共振成像技术用于识别冠状动脉微血管功能障碍
本研究连续纳入75例心绞痛合并非阻塞性冠状动脉疾病患者,以有创冠状动脉血流储备<2.5定义冠状动脉微血管功能障碍,评估3T心脏磁共振定量灌注技术的诊断准确性。结果显示,定量指标中心内膜下心肌灌注储备和透壁心肌灌注储备的AUC分别为0.90和0.88,均优于视觉评估(准确度58%),而定量负荷心肌血流的诊断效能与视觉分析相似(AUC 0.64 vs 0.60,p=0.69)。结论认为高分辨率心脏磁共振仅在定量分析时对检测冠状动脉微血管功能障碍具有良好准确性。
要点
- 定量心内膜下心肌灌注储备(MPRENDO)和透壁心肌灌注储备(MPR)诊断CMD的AUC分别为0.90和0.88,均优于视觉评估。
- 视觉评估诊断CMD的准确度为58%,敏感度41%,特异度83%。
- 定量负荷心肌血流(stress MBF)与视觉分析诊断效能相似(AUC 0.64 vs 0.60,p=0.69)。
核心结论
- 高分辨率心脏磁共振对检测冠状动脉微血管功能障碍具有良好准确性,但仅在定量分析时如此;省略静息成像和仅负荷方案虽扫描更快,但与整合静息和负荷灌注相比牺牲了准确性。
研究设计与样本
- 连续纳入心绞痛合并非阻塞性冠状动脉疾病患者75例(年龄57±10岁,81%为女性),行3T心脏磁共振检查,以有创冠状动脉血流储备<2.5定义CMD,CMR阅片者对分类设盲,比较视觉与定量灌注技术的诊断效能。
诊断标准与关键数值
- CMD定义为有创冠状动脉血流储备<2.5;定量指标包括负荷心肌血流量(stress MBF)、透壁心肌灌注储备(MPR:MBFHYPEREMIA/MBFREST)和心内膜下心肌灌注储备(MPRENDO);MPRENDO和MPR的AUC分别为0.90和0.88,视觉评估准确度58%、敏感度41%、特异度83%,stress MBF与视觉分析AUC 0.64 vs 0.60(p=0.69)。
临床应用与阅片要点
- 作者认为定量灌注心脏磁共振在心绞痛合并非阻塞性冠状动脉疾病患者的管理中角色日益重要;定量分析(MPRENDO和MPR)较视觉评估和仅负荷方案能更准确识别CMD。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study assessed the ability to identify coronary microvascular dysfunction (CMD) in patients with angina and nonobstructive coronary artery disease (NOCAD) using high-resolution cardiac magnetic resonance (CMR) and hypothesized that quantitative perfusion techniques would have greater accuracy than visual analysis.
BACKGROUND: Half of all patients with angina are found to have NOCAD, while the presence of CMD portends greater morbidity and mortality, it now represents a modifiable therapeutic target. Diagnosis currently requires invasive assessment of coronary blood flow during angiography. With greater reliance on computed tomography coronary angiography as a first-line tool to investigate angina, noninvasive tests for diagnosing CMD warrant validation.
METHODS: Consecutive patients with angina and NOCAD were enrolled. Intracoronary pressure and flow measurements were acquired during rest and vasodilator-mediated hyperemia. CMR (3-T) was performed and analyzed by visual and quantitative techniques, including calculation of myocardial blood flow (MBF) during hyperemia (stress MBF), transmural myocardial perfusion reserve (MPR: MBFHYPEREMIA / MBFREST), and subendocardial MPR (MPRENDO). CMD was defined dichotomously as an invasive coronary flow reserve <2.5, with CMR readers blinded to this classification.
RESULTS: A total of 75 patients were enrolled (57 ± 10 years of age, 81% women). Among the quantitative perfusion indices, MPRENDO and MPR had the highest accuracy (area under the curve [AUC]: 0.90 and 0.88) with high sensitivity and specificity, respectively, both superior to visual assessment (both p < 0.001). Visual assessment identified CMD with 58% accuracy (41% sensitivity and 83% specificity). Quantitative stress MBF performed similarly to visual analysis (AUC: 0.64 vs. 0.60; p = 0.69).
CONCLUSIONS: High-resolution CMR has good accuracy at detecting CMD but only when analyzed quantitatively. Although omission of rest imaging and stress-only protocols make for quicker scans, this is at the cost of accuracy compared with integrating rest and stress perfusion. Quantitative perfusion CMR has an increasingly important role in the management of patients frequently encountered with angina and NOCAD.
引用
- Rahman H, Scannell CM, Demir OM, et al. High-Resolution Cardiac Magnetic Resonance Imaging Techniques for the Identification of Coronary Microvascular Dysfunction. JACC Cardiovasc Imaging. 2020. PMID: 33248969. doi:10.1016/j.jcmg.2020.10.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。