文献速递胸部CT

深度学习分析在胸部CT上提供准确的COVID-19诊断

Deep learning analysis provides accurate COVID-19 diagnosis on chest computed tomography.
PubMed 文献 · Eur J Radiol · 2020-11-04

研究利用开源数据集6868张胸部CT图像(来自418例患者)开发深度学习机器学习分类器,并在90例独立测试集上评估,模型整体AUC为0.956,纳入阈值下敏感度84.4%、特异度93.3%,与放射科医师无差异(p>0.05);排除阈值下敏感度100%、特异度60%,与放射科医师有显著差异(p<0.05)。

要点

  • 模型在独立测试集90例患者上整体AUC为0.956。
  • 纳入阈值下敏感度84.4%、特异度93.3%,与两位放射科医师无显著差异(p>0.05)。
  • 排除阈值下敏感度100%、特异度60%,与放射科医师有显著差异(p<0.05)。

核心结论

  • 使用开源CT图像数据和基础深度学习方法准确诊断COVID-19是可行的。
  • 机器学习分类器提供了经过验证的纳入和排除标准,可用于对COVID-19存在的风险进行分层。

研究设计与样本

  • 开发了一种新的深度学习衍生机器学习分类器,采用简化编程方法和开源数据集。
  • 数据集包含来自418例患者的6868张胸部CT图像,分为训练集和验证集。
  • 在独立测试数据集上评估诊断性能,并与经验丰富的放射科医师比较。
  • 使用受试者工作特征(ROC)分析计算诊断性能指标。

诊断标准与关键数值

  • 模型在90例独立测试数据集上整体准确率(AUC)为0.956。
  • 纳入操作点:敏感度84.4%、特异度93.3%,与两位放射科医师无显著差异(p>0.05)。
  • 排除操作点:敏感度100%、特异度60%,与放射科医师有显著差异(p<0.05)。
  • 识别并验证了高阳性似然比(>10)和低阴性似然比(<0.01)的操作点,用于分层COVID-19存在的风险。

临床应用与阅片要点

  • 模型提供的纳入和排除标准可用于对COVID-19存在的风险进行分层。
  • 似然比和Fagan列线图提供了不依赖患病率的测试性能估计。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Computed Tomography is an essential diagnostic tool in the management of COVID-19. Considering the large amount of examinations in high case-load scenarios, an automated tool could facilitate and save critical time in the diagnosis and risk stratification of the disease.

METHODS: A novel deep learning derived machine learning (ML) classifier was developed using a simplified programming approach and an open source dataset consisting of 6868 chest CT images from 418 patients which was split into training and validation subsets. The diagnostic performance was then evaluated and compared to experienced radiologists on an independent testing dataset. Diagnostic performance metrics were calculated using Receiver Operating Characteristics (ROC) analysis. Operating points with high positive (>10) and low negative (<0.01) likelihood ratios to stratify the risk of COVID-19 being present were identified and validated.

RESULTS: The model achieved an overall accuracy of 0.956 (AUC) on an independent testing dataset of 90 patients. Both rule-in and rule out thresholds were identified and tested. At the rule-in operating point, sensitivity and specificity were 84.4 % and 93.3 % and did not differ from both radiologists (p > 0.05). At the rule-out threshold, sensitivity (100 %) and specificity (60 %) differed significantly from the radiologists (p < 0.05). Likelihood ratios and a Fagan nomogram provide prevalence independent test performance estimates.

CONCLUSION: Accurate diagnosis of COVID-19 using a basic deep learning approach is feasible using open-source CT image data. In addition, the machine learning classifier provided validated rule-in and rule-out criteria could be used to stratify the risk of COVID-19 being present.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Javor D, Kaplan H, Kaplan A, et al. Deep learning analysis provides accurate COVID-19 diagnosis on chest computed tomography. Eur J Radiol. 2020. PMID: 33190102. doi:10.1016/j.ejrad.2020.109402

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。