采用全尺度气道网络流模型与氙增强双能CT评估COPD患者的肺叶通气

Lobar Ventilation in Patients with COPD Assessed with the Full-Scale Airway Network Flow Model and Xenon-enhanced Dual-Energy CT.
PubMed 文献 · Radiology · 2020-11-24

这项前瞻性研究纳入22例男性COPD患者,从氙增强双能CT图像提取结构数据,用全尺度气道网络(FAN)流模型计算气体通气动力学,并与氙增强双能CT的通气分布比较。FAN计算的肺叶通气百分比与氙增强双能CT数据呈强正相关(r=0.7,P<.001),肺叶通气变异系数95%的差值位于95%置信区间内。

要点

  • FAN模型计算的肺叶通气百分比与氙增强双能CT数据呈强正相关(r=0.7,P<.001)。
  • 肺叶通气百分比与肺气肿百分比呈负相关,与正常组织体积百分比呈正相关。
  • FAN的肺变异系数与肺功能检查结果呈负相关。

核心结论

  • 全尺度气道网络模型计算的COPD患者肺叶通气与氙增强双能CT成像数据相关。

研究设计与样本

  • 前瞻性研究,纳入22例男性COPD患者(平均年龄67岁±7[标准差]),扫描时间为2012年6月至2013年7月。
  • FAN模型从氙增强双能CT图像中提取结构数据以计算气体通气动力学。
  • 比较氙增强双能CT与FAN模型在中间横断面上的通气分布、肺叶通气百分比及以变异系数(CV)量化的通气异质性。
  • 采用一致性相关系数和Pearson相关系数衡量参数间的一致性与相关性。

诊断标准与关键数值

  • FAN计算的肺叶通气百分比与氙增强双能CT数据呈强正相关(r=0.7,P<.001)。
  • 肺叶通气变异系数95%的差值位于95%置信区间内。
  • 肺叶通气百分比与肺气肿百分比的相关性为负(氙增强双能CT:r=-0.38,P<.001;FAN:r=-0.23,P=.02)。
  • 肺叶通气百分比与正常组织体积百分比的相关性为正(氙增强双能CT:r=0.78,P<.001;FAN:r=0.45,P<.001)。
  • FAN的肺变异系数与肺功能检查结果呈负相关(CVFAN与预测第1秒用力呼气容积百分比:r=-0.75,P<.001;CVFAN与第1秒用力呼气容积占用力肺活量比值:r=-0.67,P<.001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • FAN流模型与有限功能成像数据具有极好的一致性,但在临床使用前需要进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background The full-scale airway network (FAN) flow model shows excellent agreement with limited functional imaging data but requires further validation prior to clinical use. Purpose To validate the ventilation distributions computed with the FAN flow model with xenon ventilation from xenon-enhanced dual-energy (DE) CT in participants with chronic obstructive pulmonary disease (COPD). Materials and Methods In this prospective study, the FAN model extracted structural data from xenon-enhanced DE CT images of men with COPD scanned between June 2012 and July 2013 to compute gas ventilation dynamics. The ventilation distributions on the middle cross-section plane, percentage lobar ventilation, and ventilation heterogeneity quantified by the coefficient of variation (CV) were compared between xenon-enhanced DE CT imaging and the FAN model. The relationship between the ventilation parameters with the densitometry and pulmonary function test results was demonstrated. The agreements and correlations between the parameters were measured using the concordance correlation coefficient and the Pearson correlation coefficient. Results Twenty-two men with COPD (mean age, 67 years ± 7 [standard deviation]) were evaluated. The percentage lobar ventilation computed with FAN showed a strong positive correlation with xenon-enhanced DE CT data (r = 0.7, P < .001). Ninety-five percent of lobar ventilation CV differences lay within 95% confidence intervals. Correlations of the percentage lobar ventilation were negative for percentage emphysema (xenon-enhanced DE CT: r = -0.38, P < .001; FAN: r = -0.23, P = .02) but were positive for percentage normal tissue volume (xenon-enhanced DE CT: r = 0.78, P < .001; FAN: r = 0.45, P < .001). Lung CVs of FAN revealed negative correlations with the spirometry results (CVFAN vs percentage predicted forced expiratory volume in 1 second: r = -0.75, P < .001; CVFAN vs ratio of forced expiratory volume in 1 second to forced vital capacity: r = -0.67, P < .001). Conclusion The full-scale airway network modeled lobar ventilation in patients with chronic obstructive pulmonary disease correlated with the xenon-enhanced dual-energy CT imaging data. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Parraga and Eddy in this issue.