文献速递胸部PETCT

FDG-PET纹理分析与肺癌瘤内生物学异质性相关吗

Is FDG-PET texture analysis related to intratumor biological heterogeneity in lung cancer?
PubMed 文献 · Eur Radiol · 2020-11-27

研究连续纳入85例初诊非小细胞肺癌患者,于治疗前行18F-FDG-PET/CT扫描,并扫描7个均匀填充18F-FDG的体模球体,比较肿瘤与均匀球体中纹理指数与体积的相关性。结果示纹理特征与体积呈强非线性相关,预测与实测纹理特征在对比度、相异性、ZP、GLNN、均匀性上相关性很高,能量相关性低;经体积校正后仅HILAE与总生存相关(b=-0.35,p=0.008)。作者认为这些纹理指标可能不能作为瘤内异质性标志物。

要点

  • 纹理指数与肿瘤体积呈强非线性相关,均匀体模球体也表现类似行为。
  • 对比度、相异性、ZP、GLNN、均匀性的预测与实测纹理特征相关性很高。
  • 体积校正后仅HILAE与总生存相关(b=-0.35,p=0.008)。

诊断标准与关键数值

  • 肿瘤与均匀球体中所有纹理特征均与体积呈强非线性相关。
  • 预测与实测纹理特征相关性:对比度r2=0.91、相异性r2=0.90、ZP r2=0.90、GLNN r2=0.86、均匀性r2=0.82为很高;熵r2=0.50、HILAE r2=0.53为高;能量r2=0.30为低。
  • Cox回归示体积校正后仅HILAE与总生存相关(b=-0.35,p=0.008)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We aimed at investigating the origin of the correlations between tumor volume and 18F-FDG-PET texture indices in lung cancer.

METHODS: Eighty-five consecutive patients with newly diagnosed non-small cell lung cancer (NSCLC) underwent a 18F-FDG-PET/CT scan before treatment. Seven phantom spheres uniformly filled with 18F-FDG, and covering a range of activities and volumes similar to that found in lung tumors, were also scanned. Established texture indices were computed for lung tumors and homogeneous spheres. The dependence between textural indices and volume in homogeneous spheres was modeled and then used to predict texture indices in lung tumors. Correlation analyses were carried out between predicted and texture features measured in lung tumors. Cox proportional hazards regression was used to investigate the associations between overall survival and volume-adjusted textural features.

RESULTS: All textural features showed strong, non-linear correlations with volume, both in tumors and homogeneous spheres. Correlations between predicted versus measured texture features were very high for contrast (r2 = 0.91), dissimilarity (r2 = 0.90), ZP (r2 = 0.90), GLNN (r2 = 0.86), and homogeneity (r2 = 0.82); high for entropy (r2 = 0.50) and HILAE (r2 = 0.53); and low for energy (r2 = 0.30). Cox regressions showed that among volume-adjusted features, only HILAE was associated with overall survival (b = - 0.35, p = 0.008).

CONCLUSION: We have shown that texture indices previously found to be correlated with a number of clinically relevant outcomes might not provide independent information apart from that driven by their correlation with tumor volume, suggesting that these metrics might not be suitable as intratumor heterogeneity markers.

KEY POINTS: • Associations between texture FDG-PET indices and overall survival have been widely reported in lung cancer, with tumor volume also being associated with overall survival, and therefore, it is still unclear whether the predictive power of textural indices is simply driven by this correlation. • Our results demonstrated strong non-linear correlations between textural indices and volume, showing an analogous behavior for lung tumors from patients and homogeneous spheres inserted in phantoms. • Our findings showed that texture FDG-PET indices might not provide independent information apart from that driven by their correlation with tumor volume.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Piñeiro-Fiel M, Moscoso A, Lado-Cacheiro L, et al. Is FDG-PET texture analysis related to intratumor biological heterogeneity in lung cancer? Eur Radiol. 2020. PMID: 33247345. doi:10.1007/s00330-020-07507-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。