文献速递技术与安全胸部腹部CT

体部CT中z轴扫描范围过度覆盖的发生频率及原因

Excessive z-axis scan coverage in body CT: frequency and causes.
PubMed 文献 · Eur Radiol · 2020-11-25

该研究纳入2018年3月1日至4月1日期间1531例患者的2032次体部CT检查,通过比较实际扫描长度与最佳扫描长度确定z轴过度扫描,发现66%的CT存在z轴过度扫描,头侧和足侧过度扫描分别占18.4%和48.5%,并分析了患者人口学、时间、CT吞吐量和技术员经验等影响因素。

要点

  • 体部CT中z轴过度扫描发生率为66%,足侧过度扫描(48.5%)高于头侧(18.4%)。
  • 胸部CT(89.2%)、意识改变患者(88.9%)及定位像肺尖或膈肌有误导性表现者(76.6%)过度扫描更常见。
  • 日班(66.8%)、低日扫描量CT(72.4%)及经验较少技术员操作(75.9%)的CT过度扫描更频繁。

诊断标准与关键数值

  • 过度扫描判定:实际扫描长度与最佳z轴扫描长度之差。
  • z轴过度扫描CT占全部CT的66%。
  • 头侧过度扫描占18.4%,足侧过度扫描占48.5%。
  • 55-64岁年龄组过度扫描更频繁(74%)。
  • 胸部CT过度扫描更频繁(89.2%)。

临床应用与阅片要点

  • 日常阅片和报告中可关注z轴扫描范围是否超出所需解剖区域,尤其是胸部CT和足侧范围。
  • 定位像上肺尖或膈肌有误导性表现时,注意扫描范围可能被过度扩大。
  • 意识改变患者、老年患者及经验较少技术员操作的CT需留意z轴过度扫描可能。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to determine the frequency and causing factors of excessive z-axis coverage in body CT examinations.

METHODS: A total of 2032 body CT examinations performed between 1 March and 1 April 2018 in 1531 patients were included in this study. The over-scanned length values in the z-axis for each CT examination on each patient were determined by calculating the difference between the actual scanned length and optimal scan length in the z-axis. Over-scanning and over-scanning ratios were interrogated in terms of potential underlying factors that can be affected by patient demography, time, the throughput of CT, and the experience of technologists.

RESULTS: Over-scanned CTs in z-axis were 66% of all CTs performed. CT scans were over-scanned in the cranial side in 18.4% and caudal side in 48.5% of patients. Over-scanning was found to be more frequent in 55-64-year-old age group (74%), thorax CTs (89.2%), patients with consciousness change (88.9%), patients with misleading findings related to lung apex or diaphragm on the scout images (76.6%), CTs performed in day shift (66.8 %), in CT with low daily scan (72.4%), and CT scans performed by less-experienced technologists (75.9%).

CONCLUSIONS: Over-scanning in z-axis in body CT examinations is not infrequently encountered in routine practice. Awareness of causes of over-scanning in z-axis can be helpful to prevent over-scanning in CT and unnecessary ionizing radiation exposure in patients.

KEY POINTS: • Over-scanning in z-axis frequently occurs in body CT. • The frequency of over-scanning in caudal side is higher than cranial side. • Chest CT and any CT performed in following situation were more prone to over-scanning: older patients, patients with consciousness change, presence of misleading findings on the scout images related to lung apex or diaphragm, day shift, CT with low daily scan, less-experienced technologist.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yar O, Onur MR, İdilman İS, et al. Excessive z-axis scan coverage in body CT: frequency and causes. Eur Radiol. 2020. PMID: 33241517. doi:10.1007/s00330-020-07510-4