文献速递头颈神经MR

合成MRI鉴别非角化型鼻咽癌与鼻咽良性增生的可行性研究:不同感兴趣区勾画方法的影响

Investigation of the feasibility of synthetic MRI in the differential diagnosis of non-keratinising nasopharyngeal carcinoma and benign hyperplasia using different contoured methods for delineation of the region of interest.
PubMed 文献 · Clin Radiol · 2020-11-16

前瞻性纳入50例鼻咽癌与40例鼻咽良性淋巴增生患者行合成MRI,测量T1、T2、质子密度值,比较四种感兴趣区勾画方法。良性增生的T1、T2、PD值均显著高于鼻咽癌(全病灶PD除外),单层面ROI的T2值鉴别诊断AUC为0.894、敏感度0.900、特异度0.800。不同ROI类型对弛豫时间估计影响有限,仅部分层面与其他方法的T1值存在差异。

要点

  • 良性增生的T1、T2、PD值均高于鼻咽癌,全病灶ROI的PD值除外。
  • 单层面ROI的T2值鉴别鼻咽癌与良性增生AUC 0.894、敏感度0.900、特异度0.800。
  • 不同ROI勾画方法对鼻咽病灶弛豫时间估计影响有限,仅部分层面与其他方法T1值有差异。

核心结论

  • 合成MRI定量分析有潜力鉴别鼻咽癌与鼻咽良性淋巴增生。
  • 不同ROI类型对鼻咽病灶弛豫时间估计的影响有限。

研究设计与样本

  • 前瞻性研究,纳入50例鼻咽癌与40例鼻咽良性淋巴增生患者,均行合成MRI检查。
  • 测量T1、T2、质子密度值,采用部分层面、单层面、三层面和全病灶四种ROI勾画方法。
  • 采用Student t检验或单因素方差分析比较鼻咽癌与良性增生及不同ROI间的指标,计算AUC评估鉴别性能。

关键影像表现/征象

  • 无论采用何种ROI,良性增生的T1、T2、PD值均显著高于鼻咽癌,但全病灶ROI获得的PD值除外。
  • 鼻咽病灶的T1、T2、PD值在不同ROI类型间无统计学差异,但部分层面与其他方法之间的T1值存在差异。

诊断标准与关键数值

  • 单层面ROI获得的T2值鉴别鼻咽癌与良性增生的诊断准确性最高,AUC 0.894、敏感度0.900、特异度0.800。

临床应用与阅片要点

  • 合成MRI弛豫时间定量分析有潜力用于鉴别鼻咽癌与鼻咽良性淋巴增生。
  • 勾画ROI时不同方法对弛豫时间估计影响有限,但部分层面ROI的T1值与其他方法存在差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the feasibility and preliminary diagnostic performances of relaxation times derived from synthetic magnetic resonance imaging (syMRI) for differentiating nasopharyngeal carcinoma from nasopharyngeal benign lymphoid hyperplasia, and to assess the influence of tissue segmentation method on relaxation estimates.

MATERIALS AND METHODS: Fifty participants with nasopharyngeal carcinoma (NPC) and 40 participants with benign hyperplasia (NPH) who underwent syMRI examination were enrolled prospectively. T1, T2, and proton density (PD) values were obtained from four different regions of interest (ROIs), namely, partial-section, single-section, three-sections, and whole-lesion. The metrics between NPC and NPH or among different ROIs were compared using Student's t-test or one-way ANOVA. The area under curve (AUC) was calculated to assess the performance of metrics obtained from different ROIs to differentiate NPC and NPH.

RESULTS: The T1, T2, and PD values for NPH were significantly higher than those for NPC, regardless of the type of ROI used, except for the PD value obtained from the whole-lesion ROI. The T2 values obtained from the single-section ROI showed the highest diagnostic accuracy in distinguishing NPC from NPH, with an AUC of 0.894, sensitivity of 0.900, and specificity of 0.800. Additionally, the T1, T2, and PD values for nasopharyngeal lesions showed no statistical difference among different kinds of ROI, except for the difference in T1 value between partial-section and other methods.

CONCLUSION: Quantitative analysis of syMRI has the potential to distinguish NPC from NPH. Moreover, different types of ROI showed limited influence on the relaxation time estimation for nasopharyngeal lesions.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Meng T, He H, Liu H, et al. Investigation of the feasibility of synthetic MRI in the differential diagnosis of non-keratinising nasopharyngeal carcinoma and benign hyperplasia using different contoured methods for delineation of the region of interest. Clin Radiol. 2020. PMID: 33213835. doi:10.1016/j.crad.2020.10.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。