采集参数修改与场强对动脉自旋标记脑灌注测量可重复性的影响
34名志愿者在1.5T和3T扫描仪上接受重复的3D和2D伪连续动脉自旋标记扫描,评估会话内和会话间CBF可重复性及参数变化的影响。结果显示两种场强下ASL均可重复,会话内变异系数4.0%–6.7%,会话间6.6%–14.8%,可重复性与年龄无显著相关。3T下高空间分辨率3D采集减少灰白质信号混合,降低2D与3D间灰质CBF偏差(ΔCBF=2.49 mL/100g/min,P<.001)。
要点
- ASL在1.5T和3T下CBF测量均可重复,会话内变异系数4.0%–6.7%,会话间6.6%–14.8%。
- 3T下提高空间分辨率的3D采集可减少灰白质信号混合,降低2D与3D间灰质CBF偏差。
- 标记后延迟变化引起CBF小幅偏差(ΔCBF在-3.78至2.83 mL/100g/min之间,P<.001)。
关键影像表现/征象
- 3T下提高空间分辨率的3D采集减少灰质和白质信号混合,从而降低2D与3D采集间灰质CBF偏差(ΔCBF=2.49 mL/100g/min,P<.001)。
- 标记后延迟变化引起小幅偏差,ΔCBF在-3.78(P<.001)至2.83(P<.001)mL/100g/min之间。
诊断标准与关键数值
- 会话内CBF可重复性在不同图像读出方式和场强间相似,个体内变异系数在4.0%至6.7%之间。
- 会话间个体内变异系数范围为6.6%至14.8%。
临床应用与阅片要点
- 3T下采用高空间分辨率3D采集可减少灰白质信号混合,降低2D与3D采集间灰质CBF偏差。
- 标记后延迟变化可引起CBF小幅偏差(ΔCBF在-3.78至2.83 mL/100g/min之间,P<.001),阅片和报告时需考虑采集参数差异。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Although the added diagnostic value of arterial spin-labeling is shown in various cerebral pathologies, its use in clinical practice is limited. To encourage clinical adoption of ASL, we investigated the reproducibility of CBF measurements and the effects of variations in acquisition parameters compared to the recommended ASL implementation.
MATERIALS AND METHODS: Thirty-four volunteers (mean age, 57.8 ± 17.0 years; range, 22-80 years) underwent two separate sessions (1.5T and 3T scanners from a single vendor) using a 15-channel head coil. Both sessions contained repeated 3D and 2D pseudocontinuous arterial spin-labeling scans using vendor-recommended acquisition parameters (recommendation paper-based), followed by three 3D pseudocontinuous arterial spin-labeling scans, two with postlabeling delays of 1600 and 2000 ms and one with increased spatial resolution. All scans were single postlabeling delay. Intrasession (identical acquisitions, scanned five minutes apart) and intersession (first 2D and 3D acquisitions of two sessions) reproducibility was examined as well as the effect of parameter variations on CBF.
RESULTS: Intrasession CBF reproducibility was similar across image readouts and field strengths (within-subject coefficient of variation between 4.0% and 6.7%). Intersession within-subject coefficient of variation ranged from 6.6% to 14.8%. At 3T, the 3D acquisition with a higher spatial resolution resulted in less mixing of GM and WM signal, thus decreasing the bias in GM CBF between the 2D and 3D acquisitions (ΔCBF = 2.49 mL/100g/min [P < .001]). Postlabeling delay variations caused a modest bias (ΔCBF between -3.78 [P < .001] and 2.83 [P < .001] mL/100g/min).
CONCLUSIONS: Arterial spin-labeling imaging is reproducible at both field strengths, and the reproducibility is not significantly correlated with age. Furthermore, 3T tolerates more acquisition parameter variations and allows more extensive optimizations so that 3D and 2D acquisitions can be compared.