侧脑室旁与深部白质高信号的双侧距离分区法:在衰老大脑中的方法性能评估
本研究在60例受试者(20例正常对照、20例轻度认知障碍、20例阿尔茨海默病)的MRI上评估三种白质高信号分区方法(CV、D10及基于双侧距离的新方法BD),比较各方法所得亚区体积的组间差异及与认知评分的相关性,并检验可重复性;结果显示不同分区方法诊断能力相当,BD法在量化侧脑室旁白质高信号方面具有更高一致性、更大对比度和更高诊断准确性的优势,且其侧脑室旁白质高信号与临床评分的相关性更强。
要点
- BD分区法在量化侧脑室旁白质高信号方面较CV和D10法具有更高一致性、更大对比度和更高诊断准确性。
- BD与D10法可区分阿尔茨海默病与轻度认知障碍的侧脑室旁白质高信号体积,而CV法不能。
- BD分区的侧脑室旁白质高信号与MMSE、MoCA及CDR评分的相关性高于D10和CV法。
诊断标准与关键数值
- 三种分区方法均显示阿尔茨海默病受试者侧脑室旁白质高信号体积较正常对照增加。
- BD和D10法显示阿尔茨海默病受试者侧脑室旁白质高信号体积较轻度认知障碍增加,而CV法未显示该差异。
- 侧脑室旁白质高信号与简易精神状态检查、蒙特利尔认知评估及临床痴呆评定量表评分存在显著相关性,BD分区下相关性高于D10和CV法。
- 组内相关系数:组内信度ICCA=0.998,扫描间可重复性ICCA=0.992,评分者间可重复性ICCA=0.886。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Periventricular and deep white matter hyperintensities (WMHs) in the elderly have been reported with distinctive roles in the progression of cognitive decline and dementia. However, the definition of these two subregions of WMHs is arbitrary and varies across studies. Here, we evaluate three partition methods for WMH subregions, including two widely used conventional methods (CV & D10) and one novel method based on bilateral distance (BD).
MATERIALS AND METHODS: The three partition methods were assessed on the MRI scans of 60 subjects, with 20 normal control, 20 mild cognitive impairment, and 20 Alzheimer's disease (AD). Resulting WMH subregional volumes were (1) compared among different partition methods and subject groups, and (2) tested for clinical associations with cognition and dementia. Inter-rater, intrarater, and interscan reproducibility of WMHs volumes were tested on 12 randomly selected subjects from the 60.
RESULTS: For all three partition methods, increased periventricular WMHs were found for AD subjects over normal control. For BD and D10, but not CV method, increased Periventricular WMHs were found for AD subjects over mild cognitive impairment. Significant correlations were found between PVWMHs and Mini-Mental State Examination, Montreal Cognitive Assessment, and Clinical Dementia Rating scores. Furthermore, PVWMHs under BD partition showed higher correlations than D10 and CV. High intrarater and interscan reproducibility (ICCA = 0.998 and 0.992 correspondingly) and substantial inter-rater reproducibility (ICCA = 0.886) were detected.
CONCLUSION: Different WMH partition methods showed comparable diagnostic abilities. The proposed BD method showed advantages in quantifying PVWMH over conventional CV and D10 methods, in terms of higher consistency, larger contrast, and higher diagnosis accuracy. Furthermore, the PVWMH under BD partition showed stronger clinical correlations than conventional methods.
引用
- Chen J, Mikheev AV, Yu H, et al. Bilateral Distance Partition of Periventricular and Deep White Matter Hyperintensities: Performance of the Method in the Aging Brain. Acad Radiol. 2020. PMID: 33127308. doi:10.1016/j.acra.2020.07.039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。