血管内光学相干断层扫描用于脑静脉窦成像的临床前动物研究
本研究在4只约克夏猪中建立血管内光学相干断层扫描(OCT)脑静脉窦成像的临床前动物模型,比较OCT与组织学表现。4只猪中3只获得技术成功的OCT图像,OCT可显示窦腔环境及硬脑膜动脉和引流皮质静脉,Bland-Altman分析显示OCT与组织学一致性良好。作者认为该技术在人类脑静脉窦的应用可能有助于诊断、治疗和理解多种窦疾病的病理生理,但需进一步开展人体安全性和可行性研究。
要点
- 在4只约克夏猪中,3只获得技术成功的脑静脉窦血管内OCT图像。
- OCT可显示窦腔环境及硬脑膜动脉和引流皮质静脉,平均最大直径分别为3.14 mm、135 µm和260 µm。
- Bland-Altman分析显示OCT与组织学一致性良好。
关键影像表现/征象
- OCT图像可显示窦腔环境以及硬脑膜动脉和引流皮质静脉。
- 窦、硬脑膜动脉和皮质静脉的平均最大直径分别为3.14 mm、135 µm和260 µm。
- Bland-Altman分析显示组织学与OCT图像之间一致性良好。
诊断标准与关键数值
- 以组织学为参考标准,Bland-Altman分析显示OCT图像与组织学一致性良好。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 4只猪中仅3只获得技术成功的OCT图像。
- 作者指出需进一步开展人体安全性和可行性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Imaging of the cerebral venous sinuses has evolved Substantially during the past 2 decades, and most recently intravascular sinus imaging with sonography has shed light on the pathophysiology of sinus thrombosis and intracranial hypertension. Optical coherence tomography is the highest resolution intravascular imaging technique available but has not been previously used in cerebral sinus imaging. The purpose of this study was to develop a preclinical animal model of endovascular optical coherence tomography cerebral venous sinus imaging and compare optical coherence tomography findings with histology.
MATERIALS AND METHODS: Four consecutive Yorkshire swine were selected. The superior sagittal sinus was first catheterized with a microwire, and the optical coherence tomography catheter was delivered via a monorail technique into the sinus. Luminal blood was cleared with a single arterial injection. After structural and Doppler optical coherence tomography imaging, a craniotomy was performed and the sinus and adjacent dura/veins were resected. Bland-Altman analysis was performed to compare optical coherence tomography and histology.
RESULTS: Technically successful optical coherence tomography images were obtained in 3 of 4 swine. The luminal environment and visualization of dural arteries and draining cortical veins were characterized. The average maximum diameters of the sinus, dural arteries, and cortical veins were 3.14 mm, 135 µm, and 260 µm, respectively. Bland-Altman analysis demonstrated good agreement between histology and optical coherence tomography images.
CONCLUSIONS: Endovascular optical coherence tomography imaging was feasible in this preclinical animal study. Adoption of this imaging technique in the human cerebral venous sinus could aid in the diagnosis, treatment, and understanding of the pathophysiology of various diseases of the sinus. Human safety and feasibility studies are needed.
引用
- Pasarikovski CR, Ku JC, Keith J, et al. Endovascular Cerebral Venous Sinus Imaging with Optical Coherence Tomography. AJNR Am J Neuroradiol. 2020. PMID: 33214185. doi:10.3174/ajnr.A6909